Safe Fleet FoamPro 3435-0134 Installation And Operation Manual page 10

Power-fill refill system, 12vdc/24vdc/120vac/240vac
Table of Contents

Advertisement

A Safe Fleet Brand
Installation and Operation Manual
AC Portable System
The model 3435-1020 Power-Fill AC system requires a 120 VAC standard power source with 15 amp circuit
protection. The model 3435-1021 Power-Fill AC system requires a 240 VAC standard power source with 10 amp
circuit protection. A ground fault interrupter is attached to the cord for safety. DO NOT remove the GFI from the cord
or operate the system without a GFI in the line. The tank level indicator on the panel requires 12 V DC power from
the battery or master switch. This line can be wired with 14 AWG automotive-type hookup wire.
DO NOT remove GFI from power cord.
The use of an excessively long extension cord is not recommended and will affect the performance of the system
If the power cord becomes frayed or damaged, replace the entire cord.
Unplug the main power source when unit is not in use.
Tank Level
Indicator
10
14 AWG
Battery
Level Sensor
Power ON/OFF Switch
120 VAC Power 15A
(240 VAC Power 10A–Not Shown)
GFI

Advertisement