Mainte nan ce & Care
Brush belt and brush removal & replacement
Occasional replacement of the brush belt or
brush may become necessary. If needed, please
follow instructions below.
1. Turn off machine and unplug from outlet.
Wrap hose and cord on racks.
2. Remove 2-in-1 water tank and set aside.
3. IMPORTANT: Fully recline handle.
4. Locate the belt access door and insert the flat
end of a screwdriver into the slots on the belt
access door to remove.
5. Flip the unit on its side and use a Phillips head
screwdriver to remove the screw on the red belt
cover and set screw and cover aside.
6. Remove the screw from the white pivot arm
connector and set screw and connector aside.
7. Remove the black pivot arm and brush belt. If
worn or damaged, replace with a new brush belt.
8. If necessary, the brush roll can be removed
for cleaning or replacement. To remove, rotate
the brush out of brush housing and pull brush
off axle attached to remaining end cap. The
remaining pivot arm can be removed by
removing the other pivot arm connector and
screw (this will allow for full access to brush
chamber for cleaning). Make sure "keyed" end of
metal rod is aligned with slot in pivot arm before
reassembling. Replace brush on axle, cogged-
side last. You may need to rotate brush to allow
it to slide all the way down the axle.
9. Reattach brush belt by installing onto toothed
pump pulley and then onto toothed end of
brush.
10. Reattach pivot arm, white pivot arm
connector and screw.
11. Reattach red belt cover and screw.
NOTE: Do not over tighten screws.
12. Reattach belt access door.
If you have any questions or are having trouble
removing, replacing or reinstalling your brush
belt or brush, please call BISSELL® Consumer
Care.