10
Adjustments
• No adjustment is necessary. This is carried out
in our workshops.
• However, in the event of knocks, loosening of
bolts, rough handling when pivoting the head:
* adjust screw
(K) [
SEE FIG.9
* check the squarring (for straight line cuts);
* and lock the lock-nut screw
on front and rear arms).
11
Maintenance
(the motor must be stopped)
Before carrying out any operation
disconnect the machine from the
mains
Clean the machine daily.
• Empty regularly the tank to remove muddy
deposits which could clog the pump and thus
cause premature wear.
• Wash the tray with plenty of water.
• Clean the pump.
• Store in a dry place
• Clean the rails with particular attention.
Store in a dry place, not accessible to
children.
Maintain the tools carefully.

FAULT FINDING

In the event of faulty operation refer to the tables
below to find a solution.
].
(K) (adjustment
The machine does not work
CAUSES
Not
plugged
in
properly
or
cable
damaged
No mains voltage
Switch
defective,
motor cable damaged
Motor
faulty
(no
power, unpleasant
smell)
Difficult starting
CAUSES
Single phase motor
starting condenser
The pump does not start
CAUSES
The mains lead is not
correctly connected or
is damaged
No voltage in pump
circuit or mains supply
circuit
The pump does not pump water
CAUSES
REMEDIES
-
Make sure that the
supply is correctly
plugged in (plug,
extension lead, etc)
- Check the supply
cable
- Test or have tested
by an electrician
(circuit breaker, plug,
etc)
- Have tested by an
electrician or contact
the
service
department
- Contact the service
department to have
the motor replaced
REMEDIES
-
Replace the
condenser
REMEDIES
-
Check the mains
lead
- Check the pump
circuit and mains
supply circuit
REMEDIES
-
Holding the pump of
the outlet pipe remove
it from the water and
reimmerse it
23