2.3.10  Electrical connection
This section only regards the fan-assisted version.
Carry out the electrical connection by connecting the feeder [E]
to the nearest 230 V connector block (see right for wiring
diagram) and provide a bipolar switch [G] to ensure
disconnection of the appliance when it is not operated.
The outside air suction fan [B] switches on
automatically when the temperature of the heated
air emitted from the outlets reaches about 40°C and
it switches off when the air temperature drops down
the aforementioned temperature; during the
appliance operation the fan will start up and then
stop repeatedly according to the temperature.
The air temperature is sensed by a sensor [D],
factory-mounted into the left-side 15 cm Ø warm air
outlet.
The air temperature measured by sensor [D] during
operation is transmitted to the electronic control
unit [C] controlling the revolving speed of the fan [B]
(the higher the temperature, the bigger the warm air
flow emitted into the room).
CAUTION: The feeder, though protected by a cover
made of material withstanding high temperature,
must never come into contact with the appliance
surface areas.
W A R N I N G : T h e a p p l i a n c e m u s t a l w a y s b e
disconnected from electricity during all work after
connecting chimney flue, such as installation of
cladding and mounting the mantle surround trim
(double-pole switch off).
S.
SCHEMATIC FOR ELECTRICAL CONNECTION WITH DOUBLE
POLE SWITCH - 230 V power cord
TECH 3
ENGLISH
 
29