Samson S com plus Owner's Manual

Samson S com plus Owner's Manual

Stereo compressor / limiter
Hide thumbs Also See for S com plus:

Advertisement

GAIN REDUCTION dB
30
27
24 21
18 15
12
9
6
4
2
1
EXPANDER/GATE
COMPRESSOR / LIMITER
TRIGGER
THRESHOLD
RATIO
ATTACK
-10
10
20
4:1
STEREO
GATE
KEY
COMPRESSOR
LISTEN
50
0
-30
+10
2
6
15
FAST
OFF +10
1
.3
-40
+20
dB
SLOW
dB
dB
RELEASE
SPECTRA
KEY
STEREO COMPRESSOR / LIMITER
INPUT / OUTPUT LEVEL dB
-30
-24
-18 -12
-6
-3
0
+3
+6
+9 +12 +18
CH 1
STEREO LINK
EXPANDER/GATE
RELEASE
OUTPUT
ENHANCER
TRIGGER
0
50
1
5
20
IN/OUT 1
200
.15
3
-10
+10
3
7
50
IN/OUT 2
300
.05
5
OFF
10
OFF +10
-20
+20
mSec
Sec
dB
dB
AUTO
I/O METER
GAIN REDUCTION dB
INPUT / OUTPUT LEVEL dB
30
27
24 21
18 15
12
9
6
4
2
1
-30
-24
-18 -12
-6
-3
0
+3
+6
+9 +12 +18
COMPRESSOR / LIMITER
THRESHOLD
RATIO
ATTACK
RELEASE
-10
10
4:1
50
1
GATE
GATE
KEY
LISTEN
0
-30
+10
2
6
15
200
.15
3
-10
FAST
1
.3
300
.05
5
-40
+20
SLOW
dB
dB
mSec
Sec
Sec
RELEASE
SPECTRA
KEY
AUTO
I/O METER
POWER
CH 2
CH 2
OUTPUT
ENHANCER
0
5
+10
3
7
OFF
10
-20
+20
dB

Advertisement

Table of Contents
loading

Summary of Contents for Samson S com plus

  • Page 1 GAIN REDUCTION dB INPUT / OUTPUT LEVEL dB GAIN REDUCTION dB INPUT / OUTPUT LEVEL dB 24 21 18 15 -18 -12 +9 +12 +18 24 21 18 15 -18 -12 +9 +12 +18 POWER EXPANDER/GATE COMPRESSOR / LIMITER CH 1 STEREO LINK EXPANDER/GATE COMPRESSOR / LIMITER...
  • Page 2 Samson products in the future. With proper care and adequate air circulation, your S•com plus will operate trouble free for many years.
  • Page 3: S•Com Plus Features

    ENHANCER AUTO I/O METER IN/OUT The Samson S com Plus dynamics processor utilizes the latest technology in gain management design. Here are some of its main features: • Full featured, dual channel dynamics processor including Compressor/Limiter, Expander/Gate, De-Esser and Peak Limiter.
  • Page 4: Controls And Functions

    Controls and Functions FRONT PANEL LAYOUT GAIN REDUCTION dB INPUT / OUTPUT LEVEL dB DE-ESSER LEVEL dB LIMIT 24 21 18 15 -18 -12 +9 +12 +18 STEREO LINK EXPANDER/GATE COMPRESSOR / LIMITER DE-ESSER CH 1 TRIGGER THRESHOLD RATIO ATTACK RELEASE OUTPUT LEVEL...
  • Page 5 Controls and Functions GAIN REDUCTION dB INPUT / OUTPUT LEVEL dB DE-ESSER LEVEL dB LIMIT 24 21 18 15 -18 -12 +9 +12 +18 POWER LINK CH 2 EXPANDER/GATE COMPRESSOR / LIMITER DE-ESSER TRIGGER THRESHOLD RATIO ATTACK RELEASE OUTPUT LEVEL LIMITER GATE OFF +10...
  • Page 6: Operating The S•Com Plus

    Operating The S•com plus Whether you are an experienced audio engineer, just starting out, or you just want to experiment, follow the steps below to get going. Further sections in this manual will cover basic dynamics and the associated parameters, sys- tem set-ups and applications for using dynamics processing in recording and live sound applications.
  • Page 7: Gating A Signal

    Operating The S•com plus • Now gradually turn down the THRESHOLD level and GAIN REDUCTION dB 24 21 18 15 listen for the compression. For a visual representation, the amount of compression is indicated on the GAIN ER/GATE COMP REDUCTION meter. THRESHOLD RATIO ATTAC...
  • Page 8: Using The Enhancer

    Operating The S•com plus USING THE ENHANCER The S•com plus’ ENHANCER switch can be engaged to activate the EFR (Enhanced Frequency Recovery) cir- cuit. By engaging the ENHANCER, the S•com plus EFR restores the high frequency content that can be lost when high gain reduction is applied.
  • Page 9: Dynamics Processing 101

    Dynamics Processing 101 To begin to understand dynamics processing, we must first understand what dynamics are. Dynamics, or the dynamic range of a signal or audio device, is the amount of level between the softest and loudest possible out- put. Dynamics processing is applied to a signal to manage the changes in level. Various types of processing units are available to control dynamics including Noise Gates, Expanders, Compressors, Limiters and De-Essers.
  • Page 10 Dynamics Processing 101 - Continued Soft-Knee / Hard-Knee In order to prevent harsh, unnatural envelopes on compressed signals sophisticated dynamics processors like the S•com plus feature an SKD (Smart Knee Detector) or automatic knee circuit. The Smart Knee Detector auto- matically switches from Soft-Knee when the signal is less than 10 dB over Threshold, to Hard-Knee when the sig- nal is 10db above Threshold.
  • Page 11 Applications Using the Expander/Gate to Remove Hiss and Noise The S•com plus is an extremely useful tool in reducing the level of unwanted noises. By using the Expander/Gate you can effectively fade the noise into the noise floor or abruptly turn the unwanted signal completely off. Let’s say you want to reduce the bleed or cross talk that occurs when different instruments are recorded in close proximity to each other.
  • Page 12 Applications Leveling a Vocal Track When recording a vocal track, the vocalist may change the distance between them and the microphone, or they may naturally have a lot of dynamic range in their performance. In either case, the sound engineer must decide how much compression should be used to balance the natural performance and printing a good level to tape or disk.
  • Page 13 LIVE SOUND SYSTEM WITH STEREO COMPRESSION PL1602 Mixer Left High / Mid PL 1602 16 CHANNEL LINE MIXER SAMSON TECHNOLOGIES CORP., NEW YORK, U.S.A. S / N POWER MIC 1 INPUTS BALANCED 10KΩ -30 to +4db TIP + RING - SLEEVE GND.
  • Page 14 S•com plus System Set-Ups LIVE SOUND SYSTEM WITH MULTIBAND COMPRESSION PL1602 Mixer Left High / Mid SAMSON TECHNOLOGIES CORP., NEW YORK, U.S.A. PL 1602 16 CHANNEL LINE MIXER S / N POWER MIC 1 INPUTS BALANCED 10KΩ -30 to +4db TIP + RING - SLEEVE GND.
  • Page 15: S•Com Plus Connections

    S•com plus Connections CONNECTING THE S•com plus The are several ways to interface the S•com plus to support a variety of applications. The S•com plus features servo-balanced inputs and outputs, so connecting balanced and unbalanced signals is possible without any sig- nal loss.
  • Page 16: Specifications

    Specifications System Specifications Frequency Response <10Hz to 20kHz +0 / -0.1 dB effect out, -0.4 @ 100kHz, <10Hz to 20kHz +0 / -0.1 dB effect in, -3dB @ >100kHz Dynamic range 116 dB, un-weighted, 22 Hz to 22 kHz 0.008 % typ. @ +4 dBu, 1 kHz Effect out, 0.016% effect in Crosstalk >100dB, 22 Hz to 22 kHz Operating Level...
  • Page 17 Specifications Function Switches Gate Gate or Expander Release Fast/slow Enhancer In/Out In/Out Bypass Switches the detector section to external key input Auto Sets automatic attack and release times and automated timing - program dependent I/O Meter Switches the Input/Output meter to read input or output level De-Esser In/Out Stereo Link...
  • Page 18: Block Diagram

    Block Diagram...

Table of Contents