Advantech AVAS-402 User Manual

Medical

Advertisement

Quick Links

AVAS-402
Medical Video recorder

Advertisement

Table of Contents
loading

Summary of Contents for Advantech AVAS-402

  • Page 1 AVAS-402 Medical Video recorder...
  • Page 2: Instructions For The User

    Repair of the device may only be carried out by trained service personnel. Advantech recommends that a service contract be obtained with Advantech Service and that all repairs also be carried out by them. Otherwise the correct functioning of the device may be compromised.
  • Page 3 The equipment has obvious signs of breakage. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning and keep this equipment away from humidity. Caution! To avoid short-circuiting and otherwise damaging the device, do not allow fluids to come in contact with the device.
  • Page 4 Caution! When servicing the device, always use replacement parts that are qualified to Advantech standards. Advantech Digital Healthcare cannot war-rant or endorse the safe performance of third-party replacement parts for use with our medical device.
  • Page 5: Explanation Of Graphical Symbols

    Furthermore all configurations shall comply with the system standard IEC 60601-1- 1. Anyone who connects additional equipment to the signal input part or signal output part is configuring a medical system, and is therefore, responsible that the system complies with the requirements of the system standard IEC 60601-1-1.
  • Page 6 ISO 7010-M002: Follow instructions for us...
  • Page 7: Fcc Class B

    Disposing of Old Products Within the European Union EU-wide legislation, as implemented in each member state, requires that waste electrical and electronic products carrying the mark shown at left must be disposed of separately from normal household waste. This includes monitors electrical accessories, such as signal cables or power cords.
  • Page 8: List Of Accessories

    Otherwise the correct functioning of the device may be compromised. Additional Information and Assistance Contact your distributor, sales representative, or Advantech's customer service center for technical support if you need additional assistance. Please have the following information ready before you call: ...
  • Page 9: Specifications

    SDKs and APIs provided will be described in more detail. Intended use - AVAS-402 is intended to serve as a medical video recorder for integration with hospital systems. AVAS-402 is designed for general purpose used in medical image or video related application in the hospital environment, for data collection and for dis-playing information via connecting a display.
  • Page 10 Environment Humidity 5 ~90% (non-condensing) (Storage/ Transportation) 700-1060 hPa (Operation) Pressure 500-1060 hPa (Storage/Transportation) 329.5mmX320mmX145mm Dimensions Physical (W x H x D) Characteristics Weight 4.65Kg 1.3 Dimensions Dimensions: 329.5 x 320 x 145 mm Figure 1.1 Dimensions of the AVAS-402...
  • Page 11 Figure 1.2 AVAS-402 Front Panel (1) Power button (blue light) (2) USB 3.0 Figure 1.3 AVAS-402 Rear Panel (3) RS232 (4) DVI-D (5) Display Port (6) HDMI (7) USB 2.0 (8) USB 3.0 (9) RJ-45 (10) Headphone (11) MIC...
  • Page 12: Operating Principle

    During normal use of AVAS-402 the device may become dirty and should be regularly cleaned. Steps: 1. Prepare cleaning detergent 2. Wipe AVAS-402 with a clean cloth that has been moistened in the detergent. 3. Wipe thoroughly with a clean cloth. Suggested cleaning detergent: 1. 10% Sodium HyAVAShlorite 90% water solution.
  • Page 13 data in the memory units of the storage.
  • Page 14: Intended User Profile

    Patient state: patient will not be the operator. Part of the body or type of tissue applied to or interacted with: hands, expected contact time shall be less than 1 min, and will not touch AVAS-402 so frequently once it is set up.
  • Page 15: Front View

    2.1.2 Rear View Most of I/O ports of AVAS-402 are located at the rear cover, including Display port, COM port, HDMI port, DVI-D port, Ethernet ports, USB ports and so on. Apart from the I/O ports shown in below fig 2.2, additional I/O ports are also included (not shown here) as add-on cards have been assembled to AVAS-402 for capturing and recording video.
  • Page 16 (8) USB 3.0 X 6 (9) Lan Ports (RJ-45) X 2 (10) Audio out (Headphone) (11) Audio in (MIC) NOTE: Equipotential terminal need link to hospital ground/earth system before system boot to protect operator and system...
  • Page 17: Installation Procedures

    2.2.1 Connecting the Power Cord The AVAS-402 can only be powered by connecting the power cord to its power supply (FSP500M-80PA), and pressing the power button on the front cover. Be sure to always handle the power cords by holding the plug ends only.
  • Page 18: Running The Bios Setup Program

    The setup program is stored in read-only memory. It can be accessed either when you turn on or reset the AVAS-402, by pressing the “F2 or Del” key on your keyboard immediately after powering on the computer.
  • Page 19: Installing The Drivers

    Recommended Separation Distances Between Portable and Mobile RF Communications Equipment and the AVAS-402 AVAS-402 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the model AVAS-212 can help...
  • Page 20 -402 as recommended below, according to the maximum output power of the communications equipment. Rated Maximum Output Power of Separation Distance According to Frequency of Transmitter Transmitter 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2,5 GHz d = 1,2 d = 1,2 d = 2,3...
  • Page 21 Guidance and Manufacturer’s Declaration – Electromagnetic Immunity AVAS-402 is intended for use in the electromagnetic environment specified below. The customer or the user of the model AVAS-402 should assure that it is used in such an environment. IEC 60601 Test...
  • Page 22 Guidance and Manufacturer’s Declaration – Electromagnetic Immunity The model AVAS-402 is intended for use in the electromagnetic environment specified below. The customer or the user of the model AVAS-402 should assure that it is used in such an environment. Immunity...
  • Page 23 RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which AVAS-402 is used exceeds the applicable RF compliance level above, AVAS-402 should be observed to verify normal operation.
  • Page 24: General Safety Guide

     Thermal The vent hole on the rear cover of AVAS-402 as well as system fans, CPU fan function as a cooling air flow inlet and outlet. These air inlets and outlets transfer heat from inside the computer to the cooler air outside. Do not block these holes/vents with any soft material, nor should its system fans and CPU fan be removed arbitrary.
  • Page 25: Proper Handling

    Operating the computer when it is open or missing parts can be dangerous and can damage your computer. Proper Handling Handle your AVAS-402 with care. It is made of metal, and has sensitive electronic components inside. Don’t use a damaged AVAS-402.