Mitsubishi Electric PLFY-WP32VBM-E Technical & Service Manual page 14

Ceiling cassettes
Hide thumbs Also See for PLFY-WP32VBM-E:
Table of Contents

Advertisement

PLFY-WP32VBM-E.UK PLFY-WP40VBM-E.UK PLFY-WP50VBM-E.UK
<Auto Descending Panel>
20~45
Fresh air intake hole
(
Main unit
)
160
Multi-functional casement
Indoor unit/Outdoor unit
connecting terminal block
Branch duct hole
Fresh air intake hole
187.5
(Multi-functional casement)
Suspension bolt
M10 or W3/8
Water pipe
From HBC unit:Rc3/4
60
Water pipe
To HBC unit:Rc3/4
Optional parts:
Multi-functional casement
High-efficiency filter element
Suspension bolt
lower edge
Control wire entry
I-SEE SENSOR
CORNER PANEL
(Option part)
Air intake grille
M
36
Corner pocket
Indoor unit
Ceiling
Grille
Obstacle
1500mm
or more
OCH586
Ceiling hole
860~910
20~45
810
Fresh air intake hole
Suspension bolt pitch
(Multi-functional casement)
Power supply
terminal block
For MA-Remote controller
terminal block
Fresh air intake hole
160
(Multi-functional casement)
840
Air purge valve
Drain pipe
284
377
connected to VP-25
Power supply wire,
Ceiling
Indoor unit/Outdoor unit
connecting wire entry
Grille
597
Air intake hole
Drain hole
Drain pump clean hole
and Drain emergency
M
drainage hole
M
M
Vane motor
36
500
83
Air outlet hole
950
Indoor unit
3000mm or more
Floor
20~45
(7.5)
Branch duct hole
Burring hole pitch
24
(7.5)
20~45
(
)
Connected the attached
flexible pipe or socket.
Keep approximatety
10 to 15mm space
between unit ceilling
and ceilling slab.
In case of standard grille: PLP-6BA/PLP-6BAMD
35
In case of Auto-Grille: PLP-6BAJ
In case of wireless remote
controller: PLP-6BALM
Auto vane
(Air outlet)
Emergency operation
switch<Cooling>and
Emergency Up/Down switch<Up>
Emergency operation
switch<Heating>and
Emergency Up/Down switch<Down>
DEFROST/STAND BY lamp
Receiver
Operation lamp
* In case of the optional parts Multi-functional casement
and High-efficiency filter element
Note 1. Please choose the Grille from a standard grille, Auto-Grille.
2. As for drain pipe, please use VP-25(O.D. [32 PVC TUBE.).
Drain pump inclusion.
Raise is max 850mm from the ceiling.
3. As for suspension bolt, please use M10 or W3/8. (Procured at local site)
4. Electrical box may be removed for the service purpose.
Make sure to slack the electrical wire little bit for control/power wires connection.
5. The height of the indoor unit is able to be adjusted with the grille attached.
6. For the installation of the optional high efficiency filter or optional
multi-functional casement. (Reference of the 2nd sheet of detailed Figure)
1800mm or more
1) Requires 400 mm or more space between transom and ceiling for the installation.
from floor
2) The optional high efficiency filter becomes optional multi-functional
For high
casement and concomitant use.
attachment
7. When installing the branch ducts, be sure to insulate adequately.
Otherwise condensation and dripping may occur.
(It becomes the cause of dew drops/Wear dew.)
8. As for necessary installation/service space, please refer to the under at figure.
14
Detail connecting of Branch duct(Both aspects)
90
100
100
90
Cut out hole
[175
350
[150
Cut out hole
Detail drawing of fresh air intake hole
Optional parts:
Main unit side
Multi-functional casement side
(One place)
(Four places)
Burring hole pitch
Burring hole
[125
3-[2.8
Cut out hole
[100
Ceiling
Auto-Grille
Air intake grille Up/down distance
L.L Filter
Air intake grille
Unit: mm
100 130
14-[2.8
Burring hole
Burring hole pitch
[125
Burring hole
3-[2.8
knockout hole
Ceiling
[100
Ceiling