Air-Conditioners For Building Application
INDOOR UNIT
PLFY-WP·VBM-E
OPERATION MANUAL
For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
BEDIENUNGSHANDBUCH
Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme
gründlich durchlesen.
MANUEL D'UTILISATION
Pour une utilisation correcte sans risques, veuillez lire le manuel d'utilisation en entier avant de vous servir du
climatiseur.
BEDIENINGSHANDLEIDING
Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de aircondi-
tioner gebruikt.
MANUAL DE INSTRUCCIONES
para garantizar un uso seguro y correcto.
FOR USER
FÜR BENUTZER
POUR L'UTILISATEUR
VOOR DE GEBRUIKER
PARA EL USUARIO
English (GB)
Deutsch (D)
Français (F)
Nederlands (NL)
Español (E)

Advertisement

loading

Summary of Contents for Mitsubishi Electric PLFY-WP32VBM-E

  • Page 1 Air-Conditioners For Building Application INDOOR UNIT PLFY-WP·VBM-E OPERATION MANUAL FOR USER English (GB) For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. BEDIENUNGSHANDBUCH FÜR BENUTZER Deutsch (D) Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen.
  • Page 2: Table Of Contents

    2006/66/EC Article 20 Information for end-users and Annex II. Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused. This symbol means that electrical and electronic equipment, batteries and accumulators, at their end-of- life, should be disposed of separately from your household waste.
  • Page 3: Parts Names

    2. Parts Names Indoor Unit PLFY-WP . VBM-E Filter Air outlet Fan steps 4 steps Vane Auto with swing Louver – Filter Long-life Filter cleaning indication 2,500 hr Vane Air intake Wired Remote Controller Controller interface The functions of the function buttons change depending on the screen.
  • Page 4 2. Parts Names Display The main display can be displayed in two different modes: “Full” and “Basic”. The factory setting is “Full”. To switch to the “Basic” mode, change the setting on the Main display setting. (Refer to operation manual included with remote controller.) <Full mode>...
  • Page 5: Operation

    3. Operation About the operation method, refer to the operation manual that comes with each remote controller. 3.1. Turning ON/OFF [ON] [OFF] Press the [ON/OFF] button. Press the [ON/OFF] button again. The ON/OFF lamp will light up in The ON/OFF lamp will come off, green, and the operation will start.
  • Page 6 3. Operation Note: The number of available fan speeds depends on the type of unit connected. Note also that some units do not provide an “Auto” setting. Preset temperature In the following cases, the actual fan speed generated by the unit will differ for cooling from the speed shown the remote controller display.
  • Page 7 3. Operation <Exiting the Main menu screen> <Vent. setting> Press the [F3] button to go through Press the [RETURN] button to exit the ventilation setting options in the the Main menu and return to the order of "Off", "Low", and "High". Main display.
  • Page 8: Timer

    The vane of only the target indoor unit is pointing downward. 2 After pressing the [F4] button, Manual vane angle wait approximately 15 seconds, MITSUBISHI ELECTRIC M-NET address and then check the current state LABEL The air conditioner with the of the air conditioner.
  • Page 9: Care And Cleaning

    5. Care and Cleaning Filter information If two or more indoor units are connected, filter cleaning timing for each unit may be different, depending on the filter type. will appear on the Main display The icon will appear when the filter on the main unit is due for in the Full mode when it is time to cleaning.
  • Page 10: Troubleshooting

    6. Troubleshooting Having trouble? Here is the solution. (Unit is operating normally.) Air conditioner does not heat or cool well. Clean the filter. (Airflow is reduced when the filter is dirty or clogged.) Check the temperature adjustment and adjust the set temperature. Make sure that there is plenty of space around the outdoor unit.
  • Page 11: Specifications

    6. Troubleshooting Having trouble? Here is the solution. (Unit is operating normally.) Noise is louder than specifications. The indoor operation sound level is affected by the acoustics of the particular room as shown in the following table and will be higher than the noise specification, which was measured in an echo-free room.
  • Page 13 PLFY-WP VBM-E – Main Main menu Vane·Louver·Vent. (Lossnay) High power Room Timer Cool Set temp. Auto Weekly timer OU silent mode Main display: Cursor Page Mode Temp.
  • Page 14 2 3 4 5 6 Cool Set temp. Auto Room Cool Set temp. Auto Mode Temp. Mode Temp.
  • Page 15 Room Cool Set temp. Auto Mode Temp. Cool Auto Heat 28.5 Room Room Cool Set temp. Auto Cool Set temp. Auto 28.5 Mode Temp. Mode Temp.
  • Page 16 Main Main menu Vane·Louver·Vent. (Lossnay) High power Timer Weekly timer OU silent mode Main display: Cursor Page Main Main menu Vane·Louver·Vent. (Lossnay) High power Timer Weekly timer OU silent mode Main display: Cursor Page Main Main menu Vane·Louver·Vent. (Lossnay) High power Timer Weekly timer OU silent mode...
  • Page 17 Room Cool Set temp. Auto Vent. Mode Temp. High High Main Main menu Vane·Louver·Vent. (Lossnay) High power Timer Weekly timer OU silent mode Main display: Title Cursor Page Not available Unsupported function Return: Main Main menu Vane·Louver·Vent. (Lossnay) High power Timer Weekly timer OU silent mode...
  • Page 18 Manual vane angle M-NET address Manual vane angle M-NET address Identify unit Check button Input display: Identify unit Check button Cur. Address Check Input display: Cur. Address Check Manual vane angle M-NET address The air conditioner with the vane pointing downward is Manual vane angle the target air conditioner.
  • Page 19 Room Cool Set temp. Auto Mode Temp. Main Main menu Restriction Energy saving Night setback Filter information Error information Main display: Cursor Page Filter information Please clean the filter. Press Reset button after filter cleaning. Main menu: Reset Filter information Reset filter sign? Cancel Filter information...
  • Page 21 13-14-15-16 13-15-17-19 27-29-30-31 27-30-32-34...
  • Page 22 MITSUBISHI ELECTRIC AIR CONDITIONING SYSTEMS EUROPE LTD. NETTLEHILL ROAD, HOUSTOUN INDUSTRIAL ESTATE, LIVINGSTON, EH54 5EQ, SCOTLAND, UNITED KINGDOM MITSUBISHI ELECTRIC, PLFY-WP32VBM-E*, PLFY-WP40VBM-E*, PLFY-WP50VBM-E* * : , , 1, 2, 3, · · · , 9 2006/95/EC: Low Voltage 2006/42/EC: Machinery 2004/108/EC: Electromagnetic Compatibility MITSUBISHI ELECTRIC EUROPE, B.V.
  • Page 23 <ENGLISH> English is original. The other languages versions are translation of the original. CAUTION burns or frostbite. setzt. VORSICHT kann zu Verbrennungen oder Erfrierung führen. cken zu vermeiden. Vibration zu vermeiden. L’anglais est l’original. Les versions fournies dans d’autres langues sont des tra- ductions de l’original.
  • Page 24 This product is designed and intended for use in the residential, commercial and light-industrial environment. this manual before handing it to the customer.