EnglisH

Problem
The drip tray does not
move when I turn the
button.
The on/off indicator is
on continuously but the
light ring round the 1-
cup and 2-cup buttons
are not on and these
buttons do not work.
The on/off indicator is
on continuously but the
light ring round the 1-
cup button or the 2-cup
button is not on.
I interrupted the
descaling program.
How can I restart the
descaling procedure?
The descaling program
lasted only 5 minutes.
Which type of
descaler does Philips
recommend?
Water and steam have
leaked from the bottom
of the appliance in a
fast way.
Solution
Check if there is any tape left that was used to secure the driptray and cup
tray during transport.
The lid of the appliance is not properly closed and the lock lever is not
locked. Make sure the lid is closed and the lid lever is locked.
1. When the on/off indicator is on and the light ring round the 2-cup button is
off but the light ring round the 1-cup button is on, this may indicate that there
is still enough water in the water reservoir to brew one cup of coffee, but
there is not enough water to brew two cups.
2. When there is enough water in the water reservoir for at least two cups
of coffee and the light ring round the 2-cup button is off, check if the 2-cup
button works. If the machine starts to brew coffee when you press the 2-cup
button, the light ring is broken. Take the machine to your dealer or a Philips
service centre to have the light ring replaced.
3. When the on/off indicator is on and the light ring round the 2-cup button is
on, but the light ring round the 1-cup button is off, check if the 1-cup button
works. If the machine starts to brew coffee when you press the 1-cup button,
the light ring is broken. Take the machine to your dealer or a Philips service
centre to have the light ring replaced.
Remove the Calc-Clean tool. Press the Clean/Calc-Clean button to flush the
machine once and then reinsert the Calc-Clean tool.
Something went wrong during the descaling program (the on/off button was
pressed, the Calc-Clean tool was not placed correctly or the water reservoir
was removed from the machine). Remove the Calc-Clean tool and then
reinsert it. Press the Clean/Calc-Clean button to start the descaling program
again`.
You should use a descaler based on citric acid. Under Philips type number
HD7006 you can buy a descaler specially made for SENSEO
package contains 3 sachets.
Your SENSEO
machine has a technical malfunction and has drained all water
®
for safety reasons. The machine is blocked and does not function anymore.
For assistance, please visit our website www.senseo.com or take the machine
to a Philips service centre.