AQUA FORTE Dosatech Manual page 6

Professional dosage pump
Hide thumbs Also See for Dosatech:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
DosaTech
Please read carefully through these instructions for use before installing this device.
Legenda
press briefly
press for 3 seconds
10
do not do anything for 10 seconds
sec
selection confirmed
timer (normal operating status),
pump head operating time (changeable)
time of day
timer for the use of the pump head
Operation
The DosaTech is the ideal peristaltic pump for the dosing of a liquid solution into the
piping system of your pond. The neoprene hose makes it possible to add various types
of solutions to the water of your pond.
A dosage of up to 60 cc an hour is possible. In addition, it is possible to change the
dosage every hour by operating the push button underneath the display.
In addition, the DosaTech is easy to install thanks to the compact design and the
supplied suction and injection nipples. Installation is also possible in combination with
an (existing) UV-C system. The dosing pump can then operate behind the UV-C in the
filter or in the pond, to ensure that the product is not broken down by the UV-C.
Advantages of the DosaTech:
• Dosage of up to 60 cc an hour
• Dosage separately adjustable for each hour
• Neoprene hose
• Digital indication when the pump head needs replacing
• Simple installation and maintenance
• Compact design
• Easy to combine with a UV-C unit
• Suction and injection nipples supplied
• 2-year guarantee on manufacturing faults
• Earthing provided
Safety
- Always insert the plug of the device into a socket fitted with a protective cover.
- Always comply with the electricity company's regulations with regard to any permanent
connection to the mains. If there is any doubt regarding the connection, consult a
recognised electrician or the electricity company. Always work with an earth leakage
current circuit-breaker (max. 30mA).
- Always remove the plug from the socket before carrying out any maintenance or
repair work on the unit. Never insert the plug / pull the plug from the socket when
you are standing in water or if your hands are wet.
- This device is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or a lack of experience and know-how,
unless they are under supervision or are instructed on the use of the device by a
person responsible for their safety.
- The cable of the device cannot be replaced. The complete electrical unit of he device
must be replaced if there is any damage to the power cable. Never remove the plug,
but always leave the electrical unit intact. An electrical unit with the plug removed
will no longer be covered by the guarantee.
- Never submerge this device in water.
6
dosing pump
setting the timer
reset
increase
decrease
- Never install the unit in an area subject to full sunlight.
- Only install the device in a dry and well-ventilated area.
- Keep children away from this device and from the cable.
- Remove the device if there is any risk that it might freeze during the winter months.
- This product may only be used according to the guidelines described in this manual.
- If the device is used in combination with a dosing liquid, always read through the
instructions for use for this product first. Please pay special attention to the safety
regulations.
Installation of the DosaTech (Drawings 2 & 3)
1 Determine where the device will be installed. The ideal location to install your device
is immediately behind the filter and the UV-C unit (if there is one). Always carry out
the dosage after the UV, never before!
2 Secure the device to the attachment points
3 Place the suction spout
in the container with the product to be dosed. Make sure
(C)
that the suction spout
is always positioned at the bottom of the container.
(C)
4 Fit the injection spout
at the appropriate point
(D)
behind the UV-C unit (if there is one).
DosaTech instructions for use
Important!
Never use an additional timer.
The device must always be connected to the mains.
Always test the water yourself, the system will not do this for you.
First action when the DosaTech is switched on (Drawing 1)
If the pump head has been stopped for a longer period of time, there is a risk that it
will stick. In this case, you will hear a clicking sound. This can be prevented by activating
the silicones in advance by pulling the hose to and fro twice.
As soon as the DosaTech is switched on (i.e., the plug is placed into the socket), the
programme will carry out a self-test. The display will automatically show the following,
one after the other: 8888 (display test); r and software version number; 50H or 60H
indication of the mains frequency.
Following this, the display will show the hour position of the pump head (6,000),
alternating with the time that has not been set yet (00:00). This means that the time
must be set as a first step, see Drawing 4. You enter the clock menu by holding down
the button for 3 seconds.
In this menu, it is possible to modify the hours of the day in steps of one hour by briefly
pressing the button. Press the button for 3 seconds as soon as you have reached the
correct hour. Then you can set the minutes. The minutes are increased by 1 each time
blinking (on and off) in the display
using screws (not supplied).
(H)
in the piping, which is always
(J)
EN