Main Error Codes - Overland Tandberg NEO S Series Service Manual

Tape libraries
Table of Contents

Advertisement

NEO S-Series Library Service Manual

Main Error Codes

Error
Code
Description
80
Bar Code Reader Error, cannot
initialize BCR
81
Bar Code Reader Error, no
response from BCR
82
EEPROM Error, no response
from EEPROM (located on
robotic controller)
83
Robotic controller generic
problem
84
Setting of gripper motor
parameters failed
85
Setting of slider motor
parameters failed
86
Setting of elevator motor
parameters failed
87
Setting of rotation motor
parameters failed
88
Setting of sled motor
parameters failed
89
Gripper blocked
10400666-005
User Action
Retry operation; after several
occurrences contact technical
support
Retry operation; after several
occurrences contact technical
support
Retry operation; after several
occurrences contact technical
support
Reset the unit and retry
operation. After several
occurrences contact technical
support
Reset the unit and retry
operation. After several
occurrences contact technical
support
Reset the unit and retry
operation. After several
occurrences contact technical
support
Reset the unit and retry
operation. After several
occurrences contact technical
support
Reset the unit and retry
operation. After several
occurrences contact technical
support
Reset the unit and retry
operation. After several
occurrences contact technical
support
Run 'Library Verify Test', after
several occurrences contact
technical support
©2015-20 Overland-Tandberg
Event Codes and Acronyms
Critical Component Status
Robotic probably defect
• Flexi cable to BCR not properly connected.
• Flexi cable to BCR damaged.
• Bar code engine defect.
Robotic probably defect
• Flexi cable to BCR not properly connected.
• Flexi cable to BCR damaged.
• Bar code engine defect.
Robotic probably defect
Robotic controller not working (hardware
problem, EEPROM defect).
Robotic probably defect
Robotic hardware not working (cables,
distribution boards, robotics controller).
Robotic probably defect
• Elevator distribution board defect.
• Cabling incorrect.
Robotic probably defect
• Elevator distribution board defect.
• Cabling incorrect.
Robotic probably defect
• Elevator distribution board defect.
• Cabling incorrect.
Robotic probably defect
Robotics controller defect.
Robotic probably defect
Robotics controller defect.
Robotic probably defect
• Gripper motor not connected or defect.
• Gripper motor voltage to low.
• Robotics controller or distribution boards
defect.
• Check gripper mechanism according
stiffness in movement.