Technical Data; Appliance Details; 10. Troubleshooting - KENT KCH205-002 Instructions Manual

Astro portable lpg cabinet heater
Table of Contents

Advertisement

9. TECHNICAL DATA

Model
KCH205-002

Appliance Details

• With Oxygen Depletion Safety system and Anti-tilt Safety device
• Gas consumption: 306g/h
• Gas hose: Certified gas hose according to applicable EN-standard (recommend 50mm)
• Gas regulator: Certified according to EN12864 (flow rate max. 1.5kg/h)

10. TROUBLESHOOTING

Trouble
Piezo fails to light pilot
Note: when the heater is newly con-
nected it may take 2-3 attempts to
ignite the heater
Pilot lights but will not stay lit
Pilot is large and a yellow/orange
colour
Burners are not lighting properly
Gas Input kWh
High
Med
4.2
2.6
Probable Cause
1. Cylinder gas valve is closed
2. Insufficient LP gas
3. Insufficient spark to light the pilot
1. The thermoelectric flame failure
device has not engaged
1. The heater requires a service
1. Insufficient LP Gas
2. Regulators excess flow device has
engaged
3. The heater requires a service
6
Consumption g/hr
Low
High
1.5
306
Remedy
1. Open Cylinder gas valve
2. Refill cylinder
3. Check the spark gap between
the electrode and pilot (should be
4-5mm). Adjust if necessary
1. Hold down the knob firmly for 10-
20 seconds after the pilot ignites
1. Contact your local Service Agent
1. Refill cylinder
2. Turn the cylinder off for 5 minutes
Re-light the heater leaving on low
for 30 seconds before turning to
high
3. Contact your local Service Agent
Med
Low
190
109

Advertisement

Table of Contents
loading