DO
GUIDE
SFP-10G Series
10G SFP+ Transceiver Modules
DO
Install the Module
An SFP+ (enhanced small form-factor pluggable) transceiver module plugs into the SFP+ cage of a Crestron
SFP+ Module with Dual LC Connectors
Bail Latch
in Open
Position
Top of Module
RX Optical Bore
TX Optical Bore
Dust Cap
CAUTION:
Observe electrostatic discharge (ESD) precautions when handling SFP+ transceiver
modules. Always wear a wrist strap that connects to an approved grounding source when
installing or coming into contact with the modules.
CAUTION:
To prevent damage to an SFP+ module and to any connected cables, disconnect all
cables before installing or removing a module.
NOTE:
An SFP+ module is a hot-swappable input/output (I/O) device; therefore, there is no
need to power down a Crestron device when installing or removing a module.
To install an SFP+ module into an SFP+ cage, do the following:
NOTE:
Do not remove the dust cap from the SFP+ module until directed to do so in the
following procedure. In addition, always keep the dust caps on the fiber-optic cable connectors
until ready to make a connection.
1. Verify that the bail latch is closed.
Bail Latch
in Closed Position
device.
®
SFP+ Module with Single LC Connector
Bail Latch
in Open
Position
Top of Module
TX/RX Optical Bore
Dust Cap
DO
Check the Box
QTY PRODUCT
SFP-10G-S-U and SFP-10G-S-D Only
1
Patch Cord, LC-to-SC
1
Adapter, SC-to-SC
SFP-10G-S-U-10 and SFP-10G-S-D-10 Only
10
Patch Cord, LC-to-SC
10
Adapter, SC-to-SC
Not Included: Wrist Strap, Antistatic Mat or Foam, Fiber-Optic Endface Cleaning Tools and Inspection Equipment
2. Insert the module into the SFP+ cage by doing the following:
a. Verify that the top of the module is visible.
b. With the dust cap facing you, insert the module into the SFP+ cage until the module
latches into place.
3. Remove the dust caps from the LC connectors on one end of the fiber-optic cable (patch
cord included with the SFP-10-G-S-U, SFP-10-G-S-D, SFP-10G-S-U-10, and
SFP-10G-S-D-10). Save the dust caps for future use.
NOTE:
Depending on the fiber-optic cable being used, the cable provides single or dual
LC connectors. The included patch cord provides a single LC connector on one end.
4. Inspect and clean the fiber-optic endfaces of the LC connectors.
5. Remove the dust cap from the SFP+ module. Save the dust cap for future use.