4.0 General :
Temperature : 0 to 80℃
Pressure : Max. 6.0 bar
Weight : 140 g
Accuracy : +/- 10 %
Connection : 1/4" inch NPT male
Materials : Sensor Body : Acetal Copolymer, TICONA M90
Turbine : Acetal Copolymer, TICONA M90
Stick of Paddle Wheel : #304 Stainless Steel
O-Ring : EPDM Rubber
5.0 Operation Guide
1.
Install batteries
Slide off the cover case of the battery room, and put into two AA alkaline batteries. Then slide
the cover case back. The power of two AA alkaline batteries could last for two years.
2.
Connecting fitting
The thread specification of the DigiFlow 8300T connectors is 1/4" NPT male.
3.
Programming monitoring capacity
Press "PROG" button, the "ProG" blinks on the LCD. Then press "RESET" to choose the right
value to save from the right digit. Once the value is chosen, press "PROG" button to save the
value and goes to the next digit. Repeat the above procedure to program the values for five
digits from right to left. The maximum monitoring capacity for the DigiFlow 8300T is 99999
liters.
* If there is no input for one minute during the programming procedure, the programming
procedure will be terminated and goes back to the original status.
4.
Operating
The DigiFlow 8300T automatically turns on and displays the remaining capacity when there is
water flowing through the sensor. And it automatically turns off in 10 seconds when there is no
water flowing.