Playlist/Music Player Configuration - inout Dinplayer D01-MKII User Manual

Table of Contents

Advertisement

IMPORTANT:
In case of power amplifier excessive high temperature , the thermal protection disables
the audio output. To reactivate the amplifier normal operation switch the DINplayer off
and then on again.
4.8 Input management parameters
The playing of the files takes place by activating the available logical inputs, the activation
modes are set through the TPCM MICP and MIRS parameters inserted in the
configuration files.
Mnemonic
Description of timing parameter
Setting the persistence time of the input command (time to wait before
DINplayer is able to interpret the input command) expressed in decimals of
milliseconds (value between 0 and 255 in decimal).
0 = no delay
TPCM
1 =10mSeconds
(DEFAULT=10)
2 =20mSeconds
100 = 1 second
200 = 2 seconds
250 = 2,5 seconds (max. value)
Setting Mode Input Continuous Play
0 = having terminated the playing of the codified file, requested from the
MICP
input code, DINplayer goes in standby.
(DEFAULT=1)
1 = the requested codified file is continuously played until the relevant input
code is inserted.
Setting Mode Input ReStart
0 = repeated activation or deactivating of the same input code does not
influence the playing of the relevant file. Only the activation of a different
MIRS
code can block the playing underway and activate the playing of the new
(DEFAULT=1)
requested file.
1 = in the moment in which an input code is enabled the playing of the of the
relevant file from its beginning takes place, even if it is already in play.

4.9 Playlist/music player configuration

Mnemonic
Description parameter
0= playlist NOT ACTIVE.
MPLL
1= playlist ACTVE.
(DEFAULT=1)
16= music player mode
DINplayer User Manual v.2.3
Page 18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents