Room Temperature Sensor Setting; Address Switches; Setting The Model Code (Only For Heat Pump Models) - Technibel Climatisation KPAVM93R5TA Series Installation Manual

Table of Contents

Advertisement

Available languages

Available languages

5-2. Room Temperature Sensor Setting

The room temperature sensors are built into the indoor unit
and the wireless remote controller. Either of these room
temperature sensors can operate.
Heat pump models
The system is shipped from the factory set to the indoor unit
sensor. To switch to the remote controller sensor, press the
sensor switching button (* mark) on the rear of the remote
controller and check that A/C SENSOR on the LCD display
EG
panel goes out.
Cooling only models
To switch to the remote controller sensor, press the A/C
SENSOR button on the remote controller and check that
the
mark on the LCD display panel goes out. (Fig. 5-4).
NOTE
If the sensor switch is set to the remote controller side, but
no room temperature data is sent to the main unit for 10
minutes, the sensor is automatically switched to the indoor
unit side. As much as possible, install the remote controller
facing the unit.
5-3.

Address Switches

• Heat pump models
If you are installing more than 1 indoor unit (up to 3) in the same room, it is necessary for you to assign each unit its own address
so they each can be operated by their remote controller.
Up to 3 indoor units can be controlled separately through the address switches. The operating control has the reception address
switch and the remote controller has transmission address switch. This function is utilised by matching the transmission and
reception address switches.
EX) 3 indoor units in 1 room
Operating indoor units A, B, and C with their own remote controllers
Main
Indoor unit address switch
unit type
position (reception)
A unit
B unit
C unit
* Reception may be impossible if the remote controller is too far away. In this case, either use individual control or group control.
• Cooling only models
The address switch setting function is not available on the remote controller. Be sure to set the ADDRESS switch on the operation
controller to 1 (Fig. 5-6).
5-4. Setting the Model Code
(only for heat pump models)
Check that the model code switch within the remote controller
battery compartment matches following.(fig. 5-5)
Setting the model code
1
2
K
S
I
I
ADDRESS
ADDRESS
ADDRESS
Corresponding model
4-way discharge, Ceiling suspended
ADDRESS
SENSOR
1 2 3
A/C/RCU
H/P
MODELS
Remote controller address switch position (transmission)
ADDRESS
ADDRESS
ADDRESS
9
AIR CONDITIONER
SET TEMP.
ϒC
A
1HR.
TIMER
TEMP.
ON•I / OFF•
OFF ON
NIGHT
CLOCK
MODE
SETBACK
FLAP
HH
TIMER
SELECT
FAN SPEED
MM
ACL
A/C
SENSOR
SELECT
TIME SET
BATTERIES
S/C
MODELS
Operating indoors units A, B, C
with 1 remote controller
Align both the indoor unit and
remote controller address switch
positions at the same number.
ADDRESS SENSOR
Model code
switch
Fig. 5-5
A/C SENSOR
button