150-409-115-05, Issue 5
The capacities listed for the indoor enclosures in
load. The capacities listed for the outdoor enclosures in
solar load as described above. The "Recommended Slot Assignment for
Maximum Capacity" column assigns slots according to the following thermal
stress reduction rules:
1
Always leave at least one empty slot between adjacent doublers. The
adjacency rule only applies to the left- and right-hand sides of the
doubler. The top of one unit can be adjacent to the bottom of another,
though the latter configuration should be avoided if possible.
Rule 1 does not apply to the HRE-458 and HRE-819 enclosures
since these products have the required slot separations
already built into their design.
2
Allow as much room as possible between doublers on all four sides.
Slot assignments that do not follow the recommended
configurations in
as the above two rules are applied. Otherwise, damage may
occur to doubler units.
Vendor
Description
CHARLES
Indoor wall mount
SPC
Indoor rack and wall
mount
EDU-409 List 1
Table 5
Table 5. Indoor Enclosure Capacities
January 26, 2000
Table 5
and
Table 6
are permissible as long
EDU-409 List
Model #
1 Doubler
Capacity
CiAC2300
7
CiAC2002
2
4400-09
18
Functional Description
assume no solar
Table 6
assume a full
239 T1
Repeater
Capacity
7
2
18
13