Web Server
Enable XCD Encryption
If the XCD Method is selected, checking this box will enable the encryption of the XCD communications.
If the receiving device has the control page password enabled, you must use encryption and enter the
control page password in the Password field.
Password
This password is used to generate the encryption keys used for XCD when encryption is enabled. If
encryption is used, this password must be the control page password for the master device.
Page 26
defines the location of a script or page that can accept the data being sent via POST or
GET. For example, if the script is located at www.example.com/xw110/logger.php, the
path would be xw110/logger.php
With POST or GET requests, the information is sent using key-value pairs. An example
of what this request would look like is listed below:
XW-110:
serial=XXXXXXXXXXXX&sensor=71.2&unit=F&batteryLife=100