Connecting Picture Of The Measuring Instrument; Auto-Control Interface And Directions; Auto Adjustment Map(Rs-232C) - LG 32LN540B-CN Service Manual

Chassis : ld31b/ld36b
Table of Contents

Advertisement

LG Electronics Inc. Display Division
Establish : 12/09/15
Reform : 12/09/15
Connecting picture of the measuring instrument (On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to auto controller or push Adjustment R/C P-ONLY à
Enter the mode of White-Balance, the pattern will come out.

Auto-control interface and directions

1. Adjust in the place where the influx of light like floodlight around is blocked. (Illumination is less than 10ux).
2. Adhere closely the Color Analyzer ( CA210 ) to the module less than 10cm distance, keep it with the surface of
the Module and Color Analyzer s Prove vertically.(80~100°).
3. Aging time
-. After aging start, keep the power on (no suspension of power supply) and heat-run over 5 minutes.
-. Using no signal or POWER ONLY or the others, check the back light on.

Auto adjustment Map(RS-232C)

RS-232C COMMAND
[ CMD
ID
Wb
00
Wb
00
R Gain
G Gain
B Gain
R Cut
G Cut
B Cut
* Manual W/B process
LC36B Adjust specification
DATA ]
00
White Balance Start
ff
White Balance End
RS-232C COMMAND
[CMD ID DATA]
Cool
Mid
Warm
jg
Ja
jd
jh
Jb
je
ji
Jc
jf
using adjusts Remote control.
CENTER
(DEFAULT)
MIN
Cool
Mid
00
172
192
00
172
192
00
192
192
64
64
64
64
64
64
LG(55)C2-0661-00
MAX
Warm
192
192
192
192
172
192
64
128
64
128
64
128