Color Temperature Measure Standard Specification; Color Temperature Measure Specification; Luminance Measure Specification - LG 32LN540B-CN Service Manual

Chassis : ld31b/ld36b
Table of Contents

Advertisement

LGE
Establish : 12/08/31
Reform: 12/08/31
9.2.4 Test Condition

Color Temperature measure standard specification

Color Temperature measure specification

1)
In non-impressed condition, measure White Balance displayable as much as possible LCD module.
2)
Measuring instrument: CA-210 or a sort of Color Analyzer.
Pattern Generator : VG-828 or a sort of digital pattern generator (204 Gray)
3)
4)
Measure condition
Test pattern: 80% Full White pattern
SET condition : Contrast & Brightness Level Default
Environment condition : Dark room in the non outside light
Video menu option condition
Signal
NTSC-M
RF
PAL
NTSC-J
AV
PAL
Component
1080p
RGB
1024x768
HDMI
DTV 1080p
Luminance & Contrast measure standard specification

Luminance measure specification

1) In non-impressed condition, measure peak brightness displayable as much as possible LCD module.
2) Measuring instrument: CA-210 or a sort of Color Analyzer.
3) Pattern Generator : VG-828 or a sort of digital pattern generator(displayable Full White pattern)
4) A measurement condition
Display Division
NetCast 4.0 Low LC36B Product Specification
Picture Mode
Backlight
Color Temp.
Standard
100
W50 /M0 / C50
Standard
100
W50 /M0 / C50
Standard
100
W50 /M0 / C50
Standard
100
W50 /M0 / C50
Standard
100
W50 /M0 / C50
Standard
100
W50 /M0 / C50
Standard
100
W50 /M0 / C50
Dynamic Contrast Dynamic Color
Eye Care
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off deactivated
Off
Off
LG(51)
22
Black Level
Off
Low
Off
Auto
Off
High
Off
Auto
Off
High
NA
Off
Low
LG
47