Download Print this page

CAMDEN Lazerpoint RF RX-90v2 Installation Instructions Manual page 3

Advanced single relay receiver

Advertisement

has been reached. Back off the POT until the LED is solid again
for maximum On-Time.
Latching Mode
The RX-90v2 has a latching mode. Activating the transmitter will
latch the output relay ON. Activating the transmitter a second
time will latch the Relay OFF.
DIP1 can be set to either ON/OFF.
Adjust POT1 clockwise until the LED starts to flash. The RX-90v2
is in latching mode at this point. To remove latching mode, turn
POT 1 counter clockwise until the LED is solid again.
Note: Latching mode disables delayed mode. Transmitter
programmed as delayed mode will work as latching mode
transmitter.
Signal Strength Adjustment
For the most reliable, consistent operation, leave the signal
strength at full power. Camden RX-90v2 receiver has an
adjustment RF range. The range can be adjusted from a few feet
to full range (300 ft. LOS)
To adjust the RF range:
1. Press PB1 to enter pairing mode.
2. Press PB1 again until the LED flickers 3 times. This places
the receiver in RF range adjust mode.
3. Adjust POT1 to adust the RF range. CW to increase the
range, CCW to decrease the range.
4. Press a paired transmitter to test the range as it is being
adjusted.
5. Once the desired range is set, Press and hold PB1 until the
LED flickers 3 times. The transmitter is now back in pairing
mode. Either wait for the receiver to time out or press a
paired transmitter to exit pairing mode.
After adjusting the range you MUST adjust POT 1 for relay
timing at this point based on the mode (delay or no-delay).
Opening New Doors to
Innovation, Quality and Support!
LAZERPOINT™ RF RX-90v2 ADVANCED SINGLE RELAY RECEIVER
STEP 3
DELETING TRANSMITTERS
Delay Mode Transmitters
Set DIP1 to ON.
Pressing and holding PB1 for 8 seconds will delete all
transmitters delay mode. The LED will flash rapidly for
4 seconds to indicate erasure of the codes.
No Delay Mode Transmitters
Set DIP1 to OFF.
Pressing and holding PB1 for 8 seconds will delete all
transmitters no delay mode. The LED will flash rapidly for
4 seconds to indicate erasure of the codes.
Note that individual removal of specific codes is not possible.
6. WARRANTY
Camden Door Controls guarantees the Lazerpoint™ RF to be
free from manufacturing defects for 3 years from date of sale.
If during the first 3 years a Lazerpoint™ RF component fails to
perform correctly, it may be returned to our factory where it
will be repaired or replaced (at our discretion) without charge.
Except as stated herein, Camden extends no warranties
expressed or implied regarding function, performance or
service.
NOTE: Batteries are exempt from this warranty!
Call: 1.877.226.3369 / 905.366.3377
Visit: www.camdencontrols.com
I NSTALLATI ON INS TRUC TIONS
File: Lazerpoint RF RX-90v2
Manual .indd Rev2
Revised:
15/08/2019
Part No.: 40-82B212
Page 3 of 7

Advertisement

loading