I NSTA LLAT I O N IN S T RU CT IO N S

4. INSTALLATION

MOUNTING
The RX-90v2 receiver is designed to mount inside the automatic
door header. Screw holes are located at each end of the receiver
case, or the included velcro may also be used to hold it securely.
For dimensional information refer to RX-90v2 electrical and
mechanical Drawing on
Page
WIRING
Note: Do not use the Kinetic/Lazerpoint RF system as a Safety
device!!. If safety devices are used, always wire them directly to
the operator control box.
Refer to the RX-90v2 Wiring Diagram on
receiver as follows:
Wire the device (electric lock / operator) to the Relay output -
terminal 3 is N.O. 4 is Common, and 5 is N.C.
Connect 12 or 24 Volt AC or DC to terminals 1 & 2 on the receiver.
(The terminals are not polarity sensitive)
Terminal
1
2
3
4
5
5. SET-UP INSTRUCTIONS
STEP 1
Learning the Transmitter(s) to the Receiver
A receiver can have up to 40 transmitters paired with it. The
transmitter can be paired as Kinetic™/ Lazerpoint™ delayed,
non-delayed or a combination of both, making RX-90v2 ideal
for bi-directional door sequencing.
POT1
Set the RF Transmitter Type
Set DIP2 to ON Kinetic™, DIP2 to OFF Lazerpoint™
Learning the Transmitter in Delayed Mode
Set DIP1 to ON.
Press the PB1 button using a small blunt object such as a small
Page 2 of 7
4.
Page
5, and wire the
Description
Power in
Power in
Normally Open
Common
Normally Closed
ON
1
2
PB1
blade screwdriver or similar. Within 10 seconds, press the switch
connected to a TX-9 transmitter or a button on a Lazerpoint™
FOB or Kinetic™ switch. The Green LED Array will flash to confirm
enrolment. Repeat with any additional transmitters. Pressing
the learned transmitter again will signal the receiver that you are
finished programming and the LED will flash rapidly.
Pressing the transmitter a third time will activate the relay and
the LED, and also the device connected to the relay contacts
after the delay time set by POT1.
If you wait longer than the 10 second period, the receiver will
time out of Learn Mode and revert back to standby.
Learning the Transmitter in No-Delay Mode
Set DIP1 to OFF
Press the PB1 button using a small blunt object such as a small
blade screwdriver or similar. Within 10 seconds, press the switch
connected to a TX-9 transmitter or a button on a Lazerpoint™
FOB or Kinetic™ switch. The Green LED Array will flash to confirm
enrolment. Repeat with any additional transmitters. Pressing
the learned transmitter again will signal the receiver that you are
finished programming and the LED will flash rapidly.
Pressing the transmitter a third time will activate the relay and
the LED, and also the device connected to the relay contacts.
If you wait longer than the 10 second period, the receiver will
time out of Learn Mode and revert back to standby.
STEP 2
Adjustments
The delay before operate and the relay On-Time are controlled
by POT1.
Delayed Mode
The RX-90v2 has a delay before operate timer.
Set DIP1 to ON.
Adjust POT1 clockwise to increase the delay timer from 0 to
15 seconds. The LED will light and become brighter as the
delay time is increased and become dim as the delay time is
decreased. The LED starts to flash once the maximum delay
time has been reached. Back off the delay time until the LED is
solid again for maximum delay time.
No-Delay Mode
The RX-90v2 can be adjusted to activate the output relay
without a delay. The relay On-Time is adjustable from 1 to 30
seconds.
Set DIP1 to OFF.
Adjust POT1 Clockwise/counterclockwise to adjust the relay
On-Time (1 to 30 Seconds). To increase the time, turn the pot
clockwise, or for minimum time, turn the pot counterclockwise.
The LED will light and become brighter as the Relay On-Time is
increased. The LED starts to flash once the maximum On-Time

Advertisement