Appendix F. Mems Sensor To Multiplexer Wiring - Geokon 8032 Instruction Manual

Terminal board and 16/32-channel multiplexer
Hide thumbs Also See for 8032:
Table of Contents

Advertisement

APPENDIX F. MEMS SENSOR TO MULTIPLEXER WIRING

Up to sixteen Uniaxial MEMS sensors are connected to the Canary six-wire Multiplexer through
the weather tight strain relief fittings mounted to the Datalogger enclosure; with the final
connection made to the terminal blocks mounted on the Multiplexer. Each terminal block, or
Multiplexer channel, consists of seven clamp connections. A sample Uniaxial MEMS connection
is as follows for terminal block #1
Terminal Block
Location
Up to eight Biaxial MEMS sensors are connected to each Canary six-wire Multiplexer through
the weather tight strain relief fittings mounted to the Datalogger enclosure; with the final
connection made to the terminal blocks mounted on the Multiplexer. Each terminal block, or
Multiplexer channel, consists of seven clamp connections. A sample biaxial MEMS connection
is as follows for terminal blocks #1 and #2:
Terminal Block
Location
* Jumpers required for Sensor Power and Sensor Ground
Sensor Wire Color
1H1
1L1
White's Black
1H2
1L2
Green's Black
1H3
1L3
Red's Black
Shield
Table 10 - Uniaxial MEMS Wiring
Sensor Wire Color
1H1
1L1
White's Black
1H2
1L2
Blue's Black
1H3
1L3
Red's Black *
Shield
2H1
2L1
Green's Black
2H2
No Connection
2L2
No Connection
2H3
2L3
Red's Black *
Shield
Table 11 - Biaxial MEMS Wiring
Description
White
MEMS Output +
MEMS Output -
Green
Thermistor Output+
Thermistor Output-
Red
+12V Power
Power Ground
Bare
Cable Shield
Description
White
A axis Output +
A axis Output -
Blue
Thermistor Output+
Thermistor Output-
Red *
+12V Power
Power Ground
Bare
Cable Shield
Green
B axis Output +
B axis Output -
Red *
+12V Power
Power Ground
Bare
Cable Shield
--
--
19