20
APPENDIX F – MEMS SENSOR TO MULTIPLEXER WIRING
Up to sixteen (16) Uniaxial MEMS sensors are connected to the Canary 6 wire
Multiplexer through the weather tight strain relief fittings mounted to the Datalogger
enclosure; with the final connection made to the terminal blocks mounted on the
Multiplexer. Each terminal block, or Multiplexer channel, consists of seven (7) clamp
connections. A sample Uniaxial MEMS connection is as follows for terminal block #1
Terminal Block
Location
1H1
1L1
1H2
1L2
1H3
1L3
Shield
Up to eight (8) Biaxial MEMS sensors are connected to each Canary 6 wire Multiplexer
through the weather tight strain relief fittings mounted to the Datalogger enclosure; with
the final connection made to the terminal blocks mounted on the Multiplexer. Each
terminal block, or Multiplexer channel, consists of seven (7) clamp connections. A
sample biaxial MEMS connection is as follows for terminal blocks #1 and #2:
Terminal Block
Location
1H1
1L1
1H2
1L2
1H3
1L3
Shield
2H1
2L1
2H2
2L2
2H3
2L3
Shield
Note: * Jumpers required for Sensor Power and Sensor Ground
Sensor Wire Color
White
White's Black
Green
Green's Black
Red
Red's Black
Bare
Sensor Wire Color
White
White's Black
Blue
Blue's Black
Red *
Red's Black *
Bare
Green
Green's Black
No Connection
No Connection
Red *
Red's Black *
Bare
Description
MEMS Output +
MEMS Output -
Thermistor Output+
Thermistor Output-
+12V Power
Power Ground
Cable Shield
Description
A axis Output +
A axis Output -
Thermistor Output+
Thermistor Output-
+12V Power
Power Ground
Cable Shield
B axis Output +
B axis Output -
--
--
+12V Power
Power Ground
Cable Shield