Outdoor
Radio controlled model - Electrical installation
Caution: the scoreboard must not be connected to mains before installation has been fully completed.
Mains cable (P)
Connect the cable (P) to 100-240V Electrical power supply which should be located in a waterproof case. The electrical power supply
should be protected via a bipolar 4A circuit breaker (not supplied). Bipolar circuit breaker must be easy to reach.
In case a cable set needs to be installed: control cable and wall junction box
Install the cable set as described in "Cable transmission model - Electrical installation".
Note: radio controlled model: +24V is not connected in the wall junction box (wall junction box YBJ35).
YBJ35
4
1
End of the installation
Turn on the power.
Try out the scoreboard operating functions (see operating functions).
ZI de Bel Air 44850 LE CELLIER FRANCE
IA452FRC-IM_D - Installation FRC.docx
Control cable (Q): (1) = GND = blue wire / (2) = Rx+ = white wire / (3) = Rx- = grey wire /
2
(4) = +24V = transparent wire
3
P
A
100-240V
50/60Hz
stramatel@stramatel.com Tél. +33 (0)2 40 25 46 90