1.AVERTISSEMENT
Warning:
disconnect
before any kind of maintenance.
The instrument must not be opened.
In case of failure or faulty operation send the instrument
back to the distributor or to
detailed description of the fault.
2.DESCRIPTION
Model XW40L is microprocessor based controllers suitable
for applications on medium or low temperature refrigerating
units. They are provided with 3 relay outputs to control
compressor, defrost - which can be either electrical or hot gas
- and the lights. They are also provided with 1 NTC or PTC
probe inputs, for temperature control.
The regulation is performed according to the temperature
measured by the thermostat probe with a positive differential
from the set point: if the temperature increases and reaches
set point plus differential the compressor is started and then
turned off when the temperature reaches the set point value
again.
3.KEYBOARD
To
display
and
programming mode it selects a parameter or confirm
an operation.
By holding it pressed for 3s when max or min
temperature is displayed it will be erased.
To see the max. stored temperature; in programming
mode it browses the parameter codes or increases the
displayed value. By holding it pressed for 3s the fast
freezing cycle is started.
To see the min stored temperature; in programming
mode it browses the parameter codes or decreases the
displayed value.
By holding it pressed for 3s the defrost is started.
Switch ON and OFF the light of the cold-room.
Switch ON and OFF the instrument.
KEY COMBINATIONS
To lock and unlock the keyboard.
+
To enter the programming mode.
+
+
To exit the programming mode.
3.1 To lock and unlock the keyboard
HOW TO LOCK THE KEYBOARD
Keep the
and the
than 3 s. The "POF" message will be displayed and
the keyboard is locked. At this point it is only
possible the viewing of the set point or the MAX or
Min temperature stored and to switch ON and OFF
the light, the auxilary output and the instrument.
MANUAL OF THERMOSTAT XW40L
all
electrical
connections
with a
modify
target
set
point;
keys together for more
HOW TO UNLOCK THE KEYBOARD
Keep the
more than 3 s. The "POn" message will be displayed
and the keyboard is unlocked.
3.2 Meaning of the LED
Each LED function is described in the following table :
LED
MODE
ON
The compressor is running
Programmation phase ( flashing with
Flashing
Anti-short cycle delay enabled
ON
The fan is running.
Flashing
Programmation phase ( flashing with
ON
The defrost is enabled.
Flashing
Drip time in progress
ON
The fast freezing cycle is enable
Alarm signal
ON
In "Pr2" indicates that the parameter is also
present in "Pr1
ON
The light is on
3.3 How to see the min temperature
Press and release the n key.
The "Lo" message will be displayed followed by the
minimum temperature recorded.
By pressing the n key or waiting for 5s the normal
display will be restored.
in
3.4 How to see the max temperature
Press and release the o key.
The "Hi" message will be displayed followed by the
maximum temperature recorded.
By pressing the o key or waiting for 5s the normal
display will be restored.
3.5 How to reset the max and min temperature
recorded
To reset the stored temperature, when max or min
temperature is displayed, press SET key until "rST" label starts
blinking.
N.B. : After the installation RESET the temperature
stored .
3.6 How to see and modify the set point
Push and immediately release the SET key: the
display will show the Set point value.
The SET LED start blinking.
To change the Set value push the
within 10s.
To memorise the new set point value push the SET
key again or wait 10s.
3.7 To start a manual defrost
Push the DEF key for more than 2 seconds and a
manual defrost will start.
3.8 To enter in parameters list Pr1
To enter the parameter list "Pr1" (user accessible parameters)
operate as follows:
Enter the Programming mode by pressing the
Set and DOWN key for few seconds (
start blinking).
The instrument will show the first parameter
present in "Pr1".