SPECIFICATIONS
 The Safe-Cell
®
Timeflow Push Button Valve is used in prisons, detention centres, high risk institutions,
sporting facilities, schools and public area applications
 Once activated, this timed flow product will allow water to flow for approximately 15 seconds*
Designed for easy bench installation (maximum thickness 10mm)
 Time is based on set at 500kPa, 4LPM @ 22˚C. Time is affected by temperature, flow rate and pressure
 Chrome plate finish
Note: This is a single temperature product, so if warm water is required this needs to be premixed prior to
reaching the valve. This can be done by using a CliniMix
IMPORTANT: All Safe-Cell
premises in good working order.
TECHNICAL DATA
Inlet
Outlet
Headwork
Working Pressure Range (kPa)
Maximum Working Temperature (°C)
Nominal Flow Rate (LPM)
Construction
Finish
NOTE: Galvin Engineering continually strive to improve their products. Specifications may change without
notice.
TOOLS REQUIRED
Power drill
Spanner or adjustable crescent
®
prison taps are tested in accordance with AS/NZS 3718 and leave our
Version 1, 30 August 2018, 1 of 4
®
Thermostatic Mixing Valve.
½" BSP – Male
Dome Outlet
Time flow cartridge
Min
100
Max
500
Min
5
Max
70
2.55
Brass
Chrome

Advertisement

loading

Summary of Contents for Galvin Engineering Safe-Cell 50150

  • Page 1 Working Pressure Range (kPa) Maximum Working Temperature (°C) Nominal Flow Rate (LPM) 2.55 Construction Brass Finish Chrome NOTE: Galvin Engineering continually strive to improve their products. Specifications may change without notice. TOOLS REQUIRED  Power drill  Spanner or adjustable crescent...
  • Page 2 HEX W/ELBOW x 450mm LONG INSTALLATION INSTALLATION COMPLIANCE: Galvin Engineering products must be installed in accordance with these installation instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical supply conditions must also comply to the applicable national and/or state standards.
  • Page 3 Version 2, 30 August 2018, 3 of 4 1. Fit push button & basin outlet 2. Assemble valve body   Assemble the valve body to the push Fit the push button and basin outlet into the bench.  button. Ensure the sealing o-ring is placed underneath the ...
  • Page 4 Galvin Engineering Pty Ltd will always endeavour to design and test our anti-ligature product(s) to reduce the risk of product ligature attachment that may result in serious injury or death.