3.1.2 Connection to main

Use a three pole lead with a section that suits the type of
installation.
Refer to the technical specifications of the power supply line when
choosing the power lead
Main characteristics of the power lead:
cable with double insulation and 3 coloured internal conductors
(line=brown, neutral=blue, earth=yellow-green)
internal conductors with section from 1,5mm² to 2,5mm²
outer sheath diameter from 5 to 10mm
DANGER
Check that:
1-20
the voltage and frequency of the electrical supply line
correspond to the indications on the sealing plate on
the bottom of the terminal;
the mains outlet socket to which the terminal is
connected is equipped with an earth;
the warning and danger signs are present and
legible;
failing this, notify your maintenance personnel or
contact our Assistance Service directly
DD2050