6. Battery Display

6.1
Run-Time & Capacity
1
1. When connected to equipment that is turned on, two presses of the
battery's display button will show a predicted run-time against the
given load, expressed in hours and minutes.
2. A single button press of the display, whether the battery is off or
on-load, shows a percentage figure of available capacity, to a
resolution of 1%.
3
3. When the battery is fully charged the display will indicate 100%.
4. When battery is fully-discharged the display will indicate as above.
The accuracy of the display is maintained by tracking battery performance
and adjusting calibration values to compensate for the aging of the cells.
10
2
4
6.2
Data Display
The battery display can reveal data stored in the battery's internal
microprocessor using a series of button presses:
Press x3 in 1 second
Release to see 1st menu
item: 'Pd' (voltage)
intervals & hold to
enter data mode
Press without holding
for 2nd menu item
Press twice without
holding for 3rd menu
item
Press & hold for 3
seconds to see voltage
reading
Press & hold for temper-
ature in degrees celsius
Press & hold for number
of charge/discharge
cycles