Connecting the COM Port to a User Interface
1. Insert the 8-pin end of the cable into the COM port.
2. Insert the other end of the cable into the user interface (VT100-compatible terminal
emulation) connector.
COM Port-to-Terminal/Printer
Cable or
COM Port-to-PC Cable
Set the speed of the async (VT100-compatible) terminal so it
*
matches the NAM's factory-loaded data rate of 19.2 kbps, character
length set to 8, parity set to None, and stop bits set to 1. The flow
control should be set to None or Hardware.
3. Install the supplied ferrite choke on the COM port cable. To do this, open the ferrite
choke and place it as close to the cable connector as possible. Then, close the two
halves around the cable and snap the choke shut, pressing down on the plastic
latch to secure it in place.
4. Press Return on the keyboard to display the Main Menu. If you need to configure
for other than a direct link, see the FrameSaver 9120, Technical Reference
(Document No. 9121-A2-GH30).
Ferrite
*
Choke
COM
P O
R T
2
C O
M
9
97-15792