3000003622
ACW Drive
3000003625
CW Drive
Figure 2. Dimensions - basic machine
4990497003 Date: 11/2016
General
2.4
Dimensions, Performance data & Operating
Environment
Dimensions
The dimensions of the basic TR20 are shown in figure 2 below.
Performance
The performance details and power requirements of the compressor are shown on
the product data sheet.
For additional information, the constant running torque does not exceed:
347 Nm on the standard TR20
Operating environment
The permissible/foreseen operating environment is as follows:
Ambient temperature range
Resistant to tropical rain (in operation and transit), salt and sun
Humidity level
Vibration level
Inlet depression
Orientation
Max. outlet temperature
347
154
135
382
578
TR20 Installation, Operating & Maintenance Manual
Speed range 900 - 1650 rpm
-40 to +50°C
Up to 100% RH condensing
0 to 40 Hz; ± 40 mm amplitude tested.
Not to exceed 100 mbar
See fig 4 page 8
250°C
101
103
306
441
Shaft Details