Swing Settings

1
Select COOL or HEAT with the System
Switch. They are set separately.
2
Hold down the + and - buttons together for
3 seconds.
Swing Settings
Cooling Swing
The swing setting often called "cycle
rate," "differential," or "anticipation"
is adjustable. A smaller swing setting
will cause more frequent cycles and a
larger swing setting will cause fewer
cycles.
Heating Swing
The swing setting often called "cycle
rate," "differential," or "anticipation"
is adjustable. A smaller swing setting
will cause more frequent cycles and a
larger swing setting will cause fewer
cycles.
Swing Setting Tip
Temperature swing, sometimes called
differential or cycle rate can be customized
for this individual application. For most
applications choose a swing setting that is as
long as possible without making the occupants
uncomfortable.
UG-HC 566439 1219 Nonprogrammable Thermostat
Viega Nonprogrammable Thermostat User Guide
3
To exit Swing settings, slide System Switch
to different position or wait approximately 20
seconds.
LCD will Show
Adjustment Options
The cooling swing
setting is adjustable
from ±0.2°F to ± 2°F.
For example: A swing
setting of 0.5°F will
turn the cooling on at
approximately 0.5°F
above the setpoint and
turn the cooling off at
approximately 0.5°F
Below the setpoint.
The heating swing
setting is adjustable
from ±0.2°F to ± 2°F.
For example: A swing
setting of 0.5°F will
turn the heating on at
approximately 0.5°F
below the setpoint and
turn the heating off at
approximately 0.5°F
above the setpoint.
Factory
Default
Settings
0.5
0.4
11 of 12