5. Connections

Placing in the bus cable
The module BiDi-Power can provide current for BiDiB-devices only,
which are connected subsequently to the bus line (seen from the
interface´s direction). In order to exploit the current provided by BiDi-
Power, you should mount it into the bus line before the first BiDiB-
device to supply (seen from the interface´s direction).
In case one BiDi-power is not sufficient to supply all BiDiB-devices in
one bus line, you can connect further modules BiDi-Power to the bus
line.
In this example one module BiDi-Power supplies the nodes 2 and 3, another one node no. 4.
Before the first module BiDi-Power there is a node with own power supply connected to the
BiDiBus.