Summary of Contents for tams elektronik s88-Power

  • Page 1 Power Supply for the s88 bus Manual Item numbers 44-09016 | 44-09017 tams elektronik n n n...
  • Page 2: Table Of Contents

    © Tams Elektronik GmbH All rights reserved, in particular the right of reproduction, distribution and translation. Copies, reproductions and alterations in any form require the written permission of Tams Elektronik GmbH. We reserve the right to make technical changes. Printing the manual The formatting is optimised for double-sided printing.
  • Page 3: Getting Started

    Improper use and non-observance of the instructions can lead to incalculable hazards. Prevent these dangers by carrying out the following measures:  Only use the s88-Power in closed, clean and dry rooms. Avoid moisture and splash water in the environment. After condensation has formed, wait two hours for acclimatisation before use.
  • Page 4: Operation Overview

    The s88-Power is inserted into the bus line behind the last s88 module that is still supplied by the control unit or the interface (viewed from the direction of the control unit or the interface).
  • Page 5: Connections

    (viewed from the interface). If one s88-Power is not sufficient to supply all s88 components on a bus line, you can connect additional s88-Powers. Insert them into the bus line directly in front of the module(s) to be supplied.
  • Page 6: Connection To The S88 Bus

    As soon as the LED between the two RJ 45 sockets lights up brightly, voltage is present and the s88-Power is ready for operation. If the LED is only dimly lit, the power supply to the s88- Power is interrupted (e.g. the power supply unit is de-energised).
  • Page 7: Checklist For Troubleshooting And Error Correction

    Power and/or other current suppliers connected to the s88 bus line have been damaged.  The power pack provides a too high voltage. à Check the technical data of the power supply unit. Possibly the module s88-Power and/or other current suppliers connected to the s88 bus line have been damaged. ...
  • Page 8: Technical Hotline

    4.1. Technical Hotline If you have any questions about the use of the s88-Power, our technical hotline will help you (telephone number and e-mail address on the last page). 4.2. Repairs You can send us a defective s88-Power for inspection / repair (address on the last page).
  • Page 9: Technical Data

    5. Technical data Connections Supply voltage Socket for coaxial power connector (DC power connector) outer / inner diameter: 5.5 / 2.1 mm s88 bus 2 RJ 45 connection sockets, assignment according to S88-N Electrical properties Voltage supply 12 V a.c.
  • Page 10: Warranty, Eu Conformity & Weee

    6. Warranty, EU conformity & WEEE 6.1. Guarantee bond For this product we issue voluntarily a guarantee of 2 years from the date of purchase by the first customer, but in maximum 3 years after the end of series production. The first customer is the consumer first purchasing the product from us, a dealer or another natural or juristic person reselling or mounting the product on the basis of self-employment.
  • Page 11: Eu Declaration Of Conformity

    6.2. EU Declaration of Conformity This product fulfils the requirements of the following EU directives and therefore bears the CE marking. 2001/95/EU Product Safety Directive 2015/863/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) 2014/30/EU on electromagnetic compatibility (EMC Directive).