Unpacking; Location; Levelling The Refrigerator; Electrical Connection - PRODIS NT Series User Manual

Back bar refrigeration
Table of Contents

Advertisement

01. UNPACKING

WARNING
KEEP ALL PACKAGING MATERIALS INCLUDING BOXES,
PLASTIC BAGS AND POLYTHENE OUT OF REACH OF
CHILDREN
IMPORTANT
i.
REMOVE ALL SHIPPING MATERIALS, TAPE AND
PACKAGING FROM THE BOTH OUTSIDE AND INSIDE THE
REFRIGERATOR. IF PACKAGING MATERIAL IS LEFT INSIDE
THE REFRIGERATOR IT WILL NOT FUNCTION CORRECTLY
ii.
AFTER REMOVING THE PACKAGING MAKE SURE THE
REFRIGERATOR IS IN GOOD CONDITION. IF IN DOUBT
PLEASE DO NOT INSTALL OR USE THE REFRIGERATOR AND
CONTACT YOUR SUPPLIER IMMEDIATELY.
iii.
REMOVE THE SHIPPING TAPE WHICH IS HOLDING THE
DOOR CLOSED.
iv.
REMOVE
THE
PROTECTIVE
PRESENT) FROM THE EXTERIOR BEFORE INSTALLATION.
IF THE REFRIGERATOR HAS BEEN EXPOSED TO SUN
OR
HEAT
ALLOW
THE
DOWN BEFORE REMOVING THE PROTECTIVE FILM.
iv.
REMOVE THE ACCESSORY PACK AND CHECK THE
CONTENTS, IT SHOULD CONTAIN
1 x SET OF KEYS (IF LOCK FITTED)
1 x INSTRUCTION MANUAL
1 x DIGITAL CONTROLLER MANUAL

LOCATION

WARNING
THIS REFRIGERATOR IS NOT INTENDED FOR OUTDOOR
USE. NORMAL OPERATING TEMPERATURES FOR THIS
REFRIGERATOR ARE BETWEEN 10°C AND 30°C. USE OF
THIS REFRIGERATOR OUTSIDE OF THE DEFINED OPERATING
PARAMETERS WILL AFFECT COOLING AND MAY DAMAGE
THE UNIT.
01. ENSURE THERE IS A FREE FLOW OF CLEAN
AIR AVAILABLE AT THE FRONT AND REAR OF THE
REFRIGERATOR.
02. THIS REFRIGERATOR SHOULD NOT BE INSTALLED
CLOSE TO A HEAT SOURCE (RADIATOR, STOVE OR HEATER)
OR EXPOSED TO DIRECT SUNLIGHT.
03. THE INSTALLATION LOCATION SHOULD BE FIRM AND
LEVEL AND ABLE TO SUPPORT THE FULL WEIGHT OF THE
REFRIGERATOR WHEN FULLY LOADED.
04. ALLOW AT LEAST 200MM CLEARANCE AT THE
REAR FOR PROPER AIR CIRCULATION AND EASE OF
MAINTENANCE.
05. THIS REFRIGERATOR IS NOT SUITABLE FOR
INSTALLATION IN AREAS WHERE WATER IS FREE FLOWING
OR HIGH PRESSURE WATER JETS ARE USED.
NT100818UM Rev 1.1
PLASTIC
FILM
REFRIGERATOR
TO
COOL

LEVELLING THE REFRIGERATOR

01. CARE SHOULD BE TAKEN TO ENSURE THE
REFRIGERATOR IS PERFECTLY LEVEL FOR CORRECT
OPERATION. A SPIRIT LEVEL SHOULD BE USED TO CHECK
THE UNIT IS PERFECTLY LEVEL, IF THE UNIT IS NOT LEVEL
WATER LEAKS MAY OCCUR.

ELECTRICAL CONNECTION

WARNING
ALL WIRING AND ELECTRICAL CONNECTIONS MUST
CONFORM TO NATIONAL REGULATIONS. ALL ELECTRICAL
CONNECTIONS MUST BE UNDERTAKEN BY A COMPETENT
ENGINEER OR A QUALIFIED ELECTRICIAN.
01. THIS REFRIGERATOR MUST BE PLUGGED IN TO AN
INDEPENDENT POWER SOURCE OR AN ELECTRICAL SOCKET
OF VOLTAGE AND FREQUENCY SPECIFIED. ELECTRICAL
RATING INFORMATION CAN BE FOUND ON THE DATA PLATE
OF THE REFRIGERATOR.
02. THIS REFRIGERATOR MUST BE CONNECTED TO AN
INDEPENDENT CIRCUIT BREAKER OR FUSE.
(IF
03. DUE TO POTENTIAL SAFETY HAZARDS THIS
REFRIGERATOR IS NOT RECOMMENDED FOR USE WITH AN
EXTENSION LEAD
PRE-INSTALLATION CHECK LIST
ALL REFRIGERATORS HAVE BEEN FACTORY PRESET
BEFORE SHIPMENT. ADJUSTMENTS TO THE PROGRAM OR
SETTINGS ARE NOT REQUIRED FOR A NEW REFRIGERATOR
INSTALLATION. IN ORDER TO ENSURE NORMAL
OPERATION OF THE REFRIGERATOR PLEASE REFER TO
PART III OF THIS MANUAL. ALWAYS REMEMBER THAT
CHECKING AND MONITORING OF THE REFRIGERATOR IS THE
RESPONSIBILITY OF THE OPERATOR.
IS THE REFRIGERATOR INSTALLED ON A SOLID AND
LEVEL FLOOR
HAS ALL OF THE INNER AND OUTER PACKAGING BEEN
REMOVED FROM THE UNIT?
IS THERE PROPER VENTILATION AT THE FRONT AND
REAR OF THE REFRIGERATOR?
HAS THE REFRIGERATOR BEEN CLEANED INSIDE AND
OUT?
IS THE MACHINE CORRECTLY EARTHED?
IS THE POWER TO THE MACHINE SWITCHED
ON?
IS THE REFRIGERATOR LOCATED IN A ROOM WITH AN
AMBIENT TEMPERATURE BETWEEN 10°C AND 30°C?
HAVE ALL USERS BEEN FULLY TRAINED IN THE
OPERATION OF THE REFRIGERATOR?
HAS THE REFRIGERATOR BEEN ALLOWED TO STAND
FOR A MINIMUM OF 2 HOURS?
2
PART II