Factory Test Mode

Initiates automatically upon installation of a new main control.
1) All LED's lit - 10 seconds
2) Close door
3) Vent opens/ fan activated 5 seconds /vent close – 15 seconds
4) Detergent module/Water valve energized - 45-65 seconds
Appx.
depending on model
5 min
5) Main pump energized - 55 seconds
6) Turbidity sensor calibrated and other checks - 90 seconds
7) Drain pump energized – 75 seconds
8) When 2
(In some cases it may be necessary to unplug unit to exit test mode)
NOTE: If left in factory test mode dishwasher could run for up to 75 minutes before exiting
fill starts, exit test mode by pressing "Start/Reset".