Installation - 4B Binswitch BS1V3FC Operation Manual

Capacitance point level switch
Table of Contents

Advertisement

The Binswitch may be mounted horizontally or vertically. 4B offers two mounts, SMP or the BMPG36
(see illustrations below). If the Binswitch must be located in the path of an abrasive material, use in
conjunction with the Binswitch Abrasion Shield (BAS). It is important that the Binswitch is not located in
the direct flow path of any abrasive material.
Three alternative mounting methods are available for the Binswitch, see Fig. A, B and C below:
Fig. A -
Cut and drill holes as shown and
attach mounting plate (SMP)
using six 5/16" x 3/4" (M8 x 20)
bolts, nuts and washers or use
existing mounting plate. Slide
Binswitch into position and
secure by tightening mounting
plate adaptor (BMPA).
DO NOT OVERTIGHTEN
Fig. B -
Cut holes as shown and attach
mounting gland (BMPG36) using
locknut. Slide binswitch into
position and secure using clamp.
DO NOT OVERTIGHTEN
Fig. C -
Cut and drill holes as shown and
attach mounting plate (SMP)
using six 5/16" x 3/4" (M8 x 20)
bolts, nuts and washers or use
existing mounting plate. Slide
Binswitch into abrasion shield
(BAS) and tighten BAS into
mounting plate (BMPA).
DO NOT OVERTIGHTEN

INSTALLATION

Minimum Projection
3/8" (10 mm)
Minimum Projection
3/8" (10 mm)
2"
(50 mm)
Locknut
Minimum Projection
3/8" (10 mm)
PAGE 7
Wall / Casing
Mounting Plate (SMP)
Binswitch
Mounting Plate Adaptor (BMPA)
1-1/4" Thread
Wall / Casing
Mounting Gland (BMPG36)
Binswitch
Wall / Casing
Mounting Plate (SMP)
Binswitch
Binswitch Abrasion Shield (BAS)
1-1/4" Thread
3/4" NPT Conduit
Adaptor (A34NPT)
3/4" NPT Conduit
Adaptor (A34NPT)
3/4" NPT Conduit
Adaptor (A34NPT)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Binswitch bs1v6fcBinswitch bs1v4fc

Table of Contents