This user guide details the TCAN1046V CAN (Controller Area Network) EVM transceiver operation. The
TCAN1046V CAN EVM is configurable for the SOIC package version of both TCAN1046 and
TCAN1046V. This user guide explains the EVM configurations for basic CAN evaluation, and various load
and termination settings.
...................................................................................................................
1
2
3
1
EVM PC Board
2
EVM Schematic
3
1
Jumper Connections
2
J5 Pin Definitions
3
4
Protection and Filtering Configuration
5
RC Filter and Protection Lists
Trademarks
All trademarks are the property of their respective owners.
SLLU296 - August 2018
Submit Documentation Feedback
..................................................................................................
...............................................................................................................
..............................................................................................................
........................................................................................
........................................................................................................
...........................................................................................................
.............................................................................................
....................................................................................
.............................................................................................
Copyright © 2018, Texas Instruments Incorporated
TCAN1046V Evaluation Module
Contents
..........................................................
List of Figures
List of Tables
User's Guide
SLLU296 - August 2018
TCAN1046V Evaluation Module
2
5
8
2
3
9
4
5
7
7
8
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the TCAN1046V and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Texas Instruments TCAN1046V

  • Page 1: Table Of Contents

    This user guide details the TCAN1046V CAN (Controller Area Network) EVM transceiver operation. The TCAN1046V CAN EVM is configurable for the SOIC package version of both TCAN1046 and TCAN1046V. This user guide explains the EVM configurations for basic CAN evaluation, and various load and termination settings.
  • Page 2 CAN interfaces on the device separately. CAN EVM The TCAN1046V EVM has simple connections to all necessary pins of the CAN transceiver device, and jumpers where necessary to provide flexibility for device pin and CAN bus configuration. There are test...
  • Page 3 0.1µF TP11 100pF TCAN1046VDRQ1 TP12 TP13 TP16 4.70k TP14 10µF 1µF 0.1µF Green TP18 TP15 10µF 1µF 0.1µF Green TP17 Figure 2. EVM Schematic SLLU296 – August 2018 TCAN1046V Evaluation Module Submit Documentation Feedback Copyright © 2018, Texas Instruments Incorporated...
  • Page 4: Introduction

    CANL (CAN2) via 330-Ω series resistor test point TP14 STBY (CAN2) test point TP15 VCC test point TP16 VIO test point TP17 GND test point TP18 GND test point TCAN1046V Evaluation Module SLLU296 – August 2018 Submit Documentation Feedback Copyright © 2018, Texas Instruments Incorporated...
  • Page 5: Evm Setup And Operation

    2.1.1 Power Supply (J10) The basic setup of the TCAN1046V EVM uses at the most two power supply outputs required to evaluate standard 5-V supply transceiver with possibility of 3.3-V IO level device performance. When using 5-V for supply and IO levels, connect the 5-V supply to the J10 and J11 headers. The power supplied should meet 5-V and at least 100-mA.
  • Page 6 2.1.13 TP8 Configuration This connects directly to device pin 5. Ensure JMP6 configuration is not conflicting if TP8 is used as an input connection. TCAN1046V Evaluation Module SLLU296 – August 2018 Submit Documentation Feedback Copyright © 2018, Texas Instruments Incorporated...
  • Page 7: Bus Termination Configuration

    Using CAN Bus Load, Termination, and Protection Configurations The TCAN1046V EVM has several bus termination options for both available buses. The termination on the CAN bus (CANH and CANL) can be configured with the J2 and J3 (CAN1) or J6 and J8 (CAN2) jumpers.
  • Page 8: Can Evm Configuration For Tcan1046V (Factory Installed

    C10/C13 CAN EVM Configuration for TCAN1046V (Factory Installed) The TCAN1046V device interfaces CAN protocol controllers with the physical bus in accordance to the ISO 11898 standard. This device is compatible with the ISO 11898 High Speed CAN (Controller Area Network) Physical Layer standards: 11898-2. This device is designed for use of up to 5 Mbit CAN systems, and it includes many protection features providing device and CAN network robustness.
  • Page 9: Tcan1046V Basic Block Diagram

    CAN EVM Configuration for TCAN1046V (Factory Installed) www.ti.com TCAN1046V CANH1 DOMINANT TXD1 DRIVER TIME OUT CANL1 STB1 MODE AND CONTROL LOGIC OVER TEMP GND1 UNDER VOLTAGE WAKE UP LOGIC / MONITOR Low Power Standby Bus RXD1 LOGIC OUTPUT Receiver & Monitor...
  • Page 10 STANDARD TERMS FOR EVALUATION MODULES Delivery: TI delivers TI evaluation boards, kits, or modules, including any accompanying demonstration software, components, and/or documentation which may be provided together or separately (collectively, an “EVM” or “EVMs”) to the User (“User”) in accordance with the terms set forth herein.
  • Page 11 FCC Interference Statement for Class B EVM devices NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 12 【無線電波を送信する製品の開発キットをお使いになる際の注意事項】 開発キットの中には技術基準適合証明を受けて いないものがあります。 技術適合証明を受けていないもののご使用に際しては、電波法遵守のため、以下のいずれかの 措置を取っていただく必要がありますのでご注意ください。 1. 電波法施行規則第6条第1項第1号に基づく平成18年3月28日総務省告示第173号で定められた電波暗室等の試験設備でご使用 いただく。 2. 実験局の免許を取得後ご使用いただく。 3. 技術基準適合証明を取得後ご使用いただく。 なお、本製品は、上記の「ご使用にあたっての注意」を譲渡先、移転先に通知しない限り、譲渡、移転できないものとします。 上記を遵守頂けない場合は、電波法の罰則が適用される可能性があることをご留意ください。 日本テキサス・イ ンスツルメンツ株式会社 東京都新宿区西新宿6丁目24番1号 西新宿三井ビル 3.3.3 Notice for EVMs for Power Line Communication: Please see http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_02.page 電力線搬送波通信についての開発キットをお使いになる際の注意事項については、次のところをご覧ください。http:/ /www.tij.co.jp/lsds/ti_ja/general/eStore/notice_02.page 3.4 European Union 3.4.1 For EVMs subject to EU Directive 2014/30/EU (Electromagnetic Compatibility Directive): This is a class A product intended for use in environments other than domestic environments that are connected to a low-voltage power-supply network that supplies buildings used for domestic purposes.
  • Page 13 Notwithstanding the foregoing, any judgment may be enforced in any United States or foreign court, and TI may seek injunctive relief in any United States or foreign court. Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2018, Texas Instruments Incorporated...
  • Page 14 IMPORTANT NOTICE FOR TI DESIGN INFORMATION AND RESOURCES Texas Instruments Incorporated (‘TI”) technical, application or other design advice, services or information, including, but not limited to, reference designs and materials relating to evaluation modules, (collectively, “TI Resources”) are intended to assist designers who are developing applications that incorporate TI products;...