INSTALLATION REQUIREMENTS

WARNING! - This unit must be installed by a licensed HVAC
contractor. Failure to do so will void warranty of the product.
1. Unit should be installed after the air handler in the
HVAC system.
2. The ductwork around the installation area should be
clean and dry to ensure proper adhesion of the gasket
materials and any tape used.
3. When installing near a furnace or heating coils, run the heating system through five (5)
full heating cycles to ensure the temperature of the Beyond by Aerus Sanctuairy unit
does not exceed 200˚F.
4. An approximate 3.5" (8.89 cm) opening will need to be cut into the existing
ductwork to install the unit properly.
Power Connection Requirements:
This device is designed for operation from a standard 24 VAC transformer. Do not connect this unit to any voltage
source above 32 volts. Doing so will cause damage to the unit. The supplied electrical wiring has two terminals for
connection to the G4 unit. For connection to a 24 volt source other than the G4, you will need to remove the two
terminals from the end of the supplied electrical wiring.
NOTE: Unit requires continuous power. Do not install where power to the unit will be cycled on and off.
METAL DUCTWORK INSTALLATION
1
1. Locate suitable area
of duct for installation.
3
3. Mark location for 3.5" opening using either the
mounting plate or included template.
4
Min. 9" x 9"
Metal Ductwork
Min. 10" x 10"
Fiberglass
Ductwork
2
2. Cut away insulation to expose metal duct (if
needed).
4
4. Cut hole in duct using 3.5" hole saw.
Air
Handler
Max. 15 ft.