Download Print this page

Earth Networks Outdoor Alerting System Strobe Instruction Manual page 4

Advertisement

Outdoor Alerting System Strobe
3. Remove the circuit board from the base by locating the two black clips and pinching them to release the
board.
4. Loosen the existing connection screws and insert the red and black wires of the second strobe directly on
top of the first strobe, matching red with red and black with black. It is important to maintain the
position of the red and black wires on the board. The red wires should be placed on the positive (+) side
and the black wires should be placed on the negative (-) side.
5. Tighten the screws to lock the wires.
6. Return the board to the base and clip back into place.
7. Screw the clear cover back onto the black base of the strobe and tighten the fastener screw.
8. This connection is complete. Go to the section titled Securing the Strobe.
Strobe - Informer – Strobe
A second option for installation is to install both strobes at the informer. This will allow approximately
200 ft between strobes, each strobe placed up to 100 ft from the informer.
1. The exposed wires of the second strobe will be connected to the green connector of the first strobe. DO
NOT install the exposed wires of the second strobe to the informer connection.
2. Loosen the existing connection screws and insert the red and black wires of the second strobe directly on
top of the first strobe, matching red with red and black with black.
EN.PM.UM76 2017022323
Earth Networks
Page 4 of 7