Electrical Connection, Control Terminals And Display Unit - Xylem HYDROVAR Watercooled Installation And Operating Instructions Manual

Electronic variable speed drive for pumps
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
5
3
1
Motor connection
(U, V, W)
6,3 x 0,8
4

Electrical connection, control terminals and Display unit

Do the hydraulic assembling first before starting the electrical connection.
a) Open the 4 screws of the cover and remove the top cover.
b) Connect the motor cable and the supply cable.
c) If required, connect the control cable for the external release contact and the thermistor (PTC). If they are
not used; these inputs have to be bridged.
Cable gland type
M20x1,5
M16x1,5
M12x1,5
Do not connect the electronic ground with the other voltage potentials!
There is only single isolation of the control voltage. Between ground and GND of the control
voltage there can occur voltage levels >100VAC! Connected relays or switches therefore
have to have double isolated contacts.
Terminals:
1
GND
2
External release (On / Off)
3
GND
4
Thermistor
2
Control terminals
Suitable cable diameter
7-13 [mm]
4,5-10 [mm]
3,5-7 [mm]
4
3
PE (ground)
Zero-point reference
Øi 3,7
Pieces
1
2
1
1
2
3
4
17
1
2
3
4
alignment
supply (L, N)
6.3 x 0,8
5
Voltage

Advertisement

Table of Contents
loading

Table of Contents