How.to.demount.system.5000; Application; Technical.characteristics; Mounting./.Installation - PR PRetrans 5104 Manual

Repeater / power supply
Hide thumbs Also See for PRetrans 5104:
Table of Contents

Advertisement

Available languages

Available languages

HOW TO DEMOUNT SYSTEM 5000
First, remember to demount the connectors with hazardous voltages.
.
20
Picture 1:
By.lifting.the.bottom.lock,.the.device.
is.detached.from.the.DIN.rail..
.
.
.
.
.
.
.
.
.
.
Picture 2:
Then,.by.lifting.the.upper.lock.and.
pulling.the.front.plate.simultaneously.
the.PCB.is.removed..
Switches.and.jumpers.can.now.be.
adjusted.
REPEATER / POWER SUPPLY
PRetrans 5104
•.1-.or.2-channel.version.
•.3-./.5-port.3.75.kVAC.galvanic.isolation.
•.Loop.supply.>.17.1.V.
•.20.programmable.measurement.ranges.
•.Universal.supply.by.AC.or.DC

Application:

•. Supply.voltage.and.safety.barrier.for.2-wire.transmitters.mounted.in.a.
hazardous.area.
•. Safety.barrier.for.analogue.current./.voltage.signals.from.hazardous.area.
•. 1.:.1.or.signal.conversion.of.analogue.current./.voltage.signals.
Technical characteristics:
•. The.20.factory-calibrated.measurement.ranges.in.the.5104.can.be.selected.
by.the.internal.DIP-switches.without.the.need.for.a.recalibration..Special.
measurement.ranges.can.be.delivered.
•. PR5104.is.based.on.microprocessor.technology.for.gain.and.offset..The.
analogue.signal.is.transmitted.at.a.response.time.of.less.than.25.ms.
•. Inputs,.outputs,.and.supply.are.floating.and.galvanically.separated.
•. The.output.can.be.connected.either.as.an.active.current./.voltage.transmitter.
or.as.a.2-wire.transmitter.
Mounting / installation:
•. Mounted.vertically.or.horizontally.on.a.DIN.rail..By.way.of.the.2-channel.
ver. s ion.up.to.84.channels.per.metre.can.be.mounted.
•. NB: 5104B.is.recommended.as.Ex.barrier.for.5331D,.5333D,.5334B,.5343B,.
6331B,.6333B,.and.6334B.
21