Clearances & Installation
Clearances & Installation
Please read these instructions completely
before operating the EcoSmart™ Fire.
DESIGNER RANGE CLEARANCES
Ensure that the mouth of the flame is positioned a minimum of
1500mm [59.1in] away from curtains, flammable materials and other
sources of ignition. Be aware of drafts.
WARNING: Keep fire at least 1500mm [59.1in] away from any
combustibles.
Aspect, Citi, Cube, Cube Jr, Oxygen, Zeta
There are no additional requirements for side and/or overhead
clearances.
Igloo, Ghost
There must be a minimum of 1500mm [59in] between the mouth of the
flame and the nearest combustible at all times.
Vision, Fusion
The Vision/Fusion is designed as a room divider but can also be
placed against any flat wall surface made out of non-combustible
material or sitting 100mm [3.95in] away from any wall of any material.
Always place the glass side closest to the wall. Even when unit is used
as a room divider, the glass side is the "rear."
www.ecosmartfire.com
Tower, Q, Retro
When used indoors there must be a minimum of 1500mm [59.1in]
between the mouth of the flame and the nearest combustible at all
times. Make sure your fire is at least this distance away from curtains,
etc. Be aware of drafts.
When used outdoors it is important that the model be positioned
in a large open space ensuring that the nearest combustible (trees,
branches, umbrellas, ceilings etc) are a minimum of 2000mm [78.74in]
away in all weather conditions (for example, on windy days where there
is movement in branches, the clearance must still be met).
When not in use it is recommended that you protect the model from
water damage or corrosion by covering. Burner covers are available.