Introduction

You have acquired a high-quality measurement instrument manufactured by
BEHA-AMPROBE, which will enable you to perform repeatable measurements
for a very long period of time.
The portable appliance tester GT-600/GT-800 is a measurement instrument used
for safety inspection on electrical appliances complying with VDE 0701-0702 and
documentation of test results.

Product description:

Protective bonding resistance measurement (R
A AC. The test is carried out on plugged and also on permanently connected
appliances.
Insulation resistance measurement (R
GT-800 only). Appliances class I with heater, class I, class II and class III can be
tested.
Substitute leakage current measurement (I
Appliances class I and class II can be tested.
Protective conductor current measurement (I
Touch current measurement (I
Apparent power, active power, mains voltage, load current and power factor
PF measurement (P/I
Protective conductor current I
clamp method (GT-800 only).
IEC CORD test (PE continuity, insulation resistance, L continuity, N continuity,
L/N shorted).
Test of portable RCD (PRCD), PE continuity, TEST button, output insulation
resistance, PE current, functional test at L disconnection, functional test at N
disconnection, trip out time at I
N
I
, tripping current (GT-800 only).
Protective extra low voltage (PELV) measurement.
Safety extra low voltage (SELV) measurement.
AUTO Test (13 factory-programmed AUTO-Tests, 17 customer-created AUTO-
Tests) (GT-800 only).
Extremely easy operation using the rotary switch and the START/STOP
button.
Automatic start function for protective bonding resistance measurement
allows both-hands measurements on measured objects that are difficult to
access.
Compensation of test lead resistance for protective bonding resistance
measurement.
Calculation of limits for protective bonding resistance.
Automatic mains voltage polarity exchange at protective conductor current
and touch current measurements (GT-800 only).
Data memory for over 1000 measurement results.
Integrated interface (USB 2.0) for transfer of measurement results to PC.
Separate interface (USB 2.0) for connection of optional USB barcode reader,
USB keyboard, USB memory stick or USB printer.
ISO
) direct method
T
).
L
and load current I
PE
N/2
, trip out time at I
7
), test current 0.2 A AC and 5
PE
), test voltage 500 VDC (and 250 VDC
), test voltage 45 V AC.
SUB
), differential method
PE()
.
measurement (
L
N
, trip out time at 5
.
),