Frico AGS5515 Installation Instructions Manual

Air curtain ags5500 series.
Hide thumbs

Advertisement

Original instructions
AGS5500
GB
.... 19

Advertisement

Table of Contents

   Related Manuals for Frico AGS5515

   Summary of Contents for Frico AGS5515

  • Page 1 Original instructions AGS5500 ..19...
  • Page 2 AGS5500 The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages.
  • Page 3 AGS5500 PC board (2 x for AGS5525/5530) SIRe AGS5515: 4 x M10 AGS5520/5525: 6 x M10 AGS5530: 8 x M10 AGS5520/5525 Inside thread [mm] AGS5515 1515 AGS5515 DN25 (1") DN20 (3/4") AGS5520 2010 AGS5520 DN32 (1 1/4") DN25 (1") AGS5525...
  • Page 4 AGS5500 min 200 Fig. 2. Minimum distance Fig. 3. Installation alternatives Fig. 4. Open the unit...
  • Page 5 AGS5500 AGS5500 + GWB640 Type Wall bracket GWB640 AGS5515 2 pcs AGS5520 3 pcs AGS5525 3 pcs 4 pcs AGS5530 GWB640 20 mm 20 mm 20 mm Fig. 5. Mounting bracket GWB640...
  • Page 6 AGS5500 SIRe SIReBN SIReAC SIReAA SIReB SIReUR SIReRTX 70x33x23 mm SIReUR 114x70x50 mm SIReWTA SIReWTA SIReCJ4 SIReCJ6 SIReCC603 SIReCC605 SIReAC/SIReAA SIReCJ4/SIReCJ6 SIReCC610 10 m SIReCC615 15 m SIReCC640 40 m SIReCC403 SIReCC405 SIReRTX SIReCC SIReCC410 10 m SIReCC415 VMO20 DN20 VMOP VMO25 DN25...
  • Page 7 AGS5500 Output charts water AGS5500WH Supply water temperature: 110 °C Water temperature: 110/80 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output* Outlet Water Pressure position water temp. flow drop air temp.
  • Page 8 AGS5500 Output charts water AGS5500 WL Supply water temperature: 80 °C Water temperature: 80/60 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output* Outlet Water Pressure position water temp. flow drop air temp.
  • Page 9 ) ∆t = temperature rise of passing air at maximum heat output and lowest/highest airflow. ) Applicable at water temperature 80/60 °C, air temperature, in +18 °C. ) Applicable at water temperature 60/40 °C, air temperature, in +18 °C. See www.frico.se for additional calculations. Protection class: IP24. CE compliant.
  • Page 10 AGS5500 AGS5515 / AGS5520 Transformer Transformer Actuator 230V Supply 230V Room 230V~...
  • Page 11 AGS5500 AGS5525 / AGS5530 Transformer Actuator 230VSupply 230V Room Transformer Transformer Actuator 230VSupply 230V Room 230V~...
  • Page 12 AGS5500 SIReB Basic AGS5500A SIReUB1 SIReRTX SIReB1/B2/B1EC (optional) 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX L=2m (max 50 m) SIReCC6XX (max 10 m) SIReB1/B2/B1EC 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX (max 50 m) SIReB1/B2/B1EC 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY Wiring diagrams for SIReAC Competent, see manual for SIRe.
  • Page 13 AGS5500 SIReB Basic AGS5500 W SIReUB1 SD230 SIReRTX SIReB1/B2/B1EC (optional) 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX L=2m (max 50 m) L=1,5m SIReCC6XX (max 10 m) SD230 SIReB1/B2/B1EC 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX (max 50 m) SD230 SIReB1/B2/B1EC 230V~...
  • Page 14 Note that the unit shall be preceded by a The efficiency of the air curtain depends regulating valve, see Frico valve kit. on the air temperature, pressure differences The water coil is connected on the upper side across the doorway and any wind pressure.
  • Page 15 AGS5500 Basic setting fan speed Fan replacement The fan speed when the door is open is set 1. Determine which of the fans is not using the control. Note that the air flow functioning. direction and fan speed may need fine 2.
  • Page 16 AGS5500 Safety • Keep the areas around the air intake and exhaust grilles free from possible obstructions! • The unit may have hot surfaces during operation and when cooling down! • Lifting equipment must be used to lift the unit. •...
  • Page 17 AGS5500...
  • Page 18 AGS5500...