Maintenance Instructions ClimaRad Sensa V2X
Maintenance frequency for filters
When should you replace the filters?
•
With normal use, every 2 years or earlier if the message 'Filter
on the display (for example in homes and offices).
•
In the case of intensive use, after 1 year or earlier if the message 'Filter
appears on the display (e.g. for care homes and schools).
Replacing air supply filters
1. Switch off the device first by
removing the plug from the
socket.
Upper side
4. Remove the black filter caps on
the left and right.
Bottom side
Upper side
7.
Close the covers on the
and bottom side of the unit, and
slide both latching slides
outwards.
Important: Reset the filter hour counter only if you have replaced
the filters.
2. Turn the two locking hooks (at
the bottom or on the side of the
housing). Remove the cover of the
Sensa by lifting it upwards.
Bottom side
Slide 3 new
filters in
5. Slide the three new filters in the
unit from the
filters will automatically slide out
on the
bottom
upper
8. Put the cover back on and turn
the locking hooks (at the bottom
or on the side of the housing).
vervuild
' appears
vervuild
3 old filters
will slide out
upper
side. The old
side.
F u t u r e c o m f o r t t o d a y
Ordering filters
Order new filters at
www.climarad.nl/filters
'
Bottom side
Upper side
3.
Push the
upper and lower slide
on the right side of the ClimaRad
inwards and open both covers by
pulling them towards you.
Upper side
Bottom side
6. Replace the black filter caps on
the upper and bottom side.
and
press for 6 seconds
9. Push the plug back into the socket
and reset the filter hour counter (by
simultaneously pressing on the + and
- on the display for 6 seconds ). The
message 'Filter
vervuild
' will
disappear. Tighten the locking screws
again.