Instantaneous water heater system WM 400 V
5.4 Waste water filtration plant
The waste water filter system is used for filtration of contaminated shower water.
In the three-stage filtration system consisting of a pre-filter (220), a pressure gauge for
filter monitoring and two fine filters (50, 1), the water is filtered and discharged through
the drain line
To achieve a constant flow pump
.
too strong fouling.
 We recommend a filter change of the two fine filter at about 3.0 bar
 The pre-filter is to clean up pollution
Filter gauge filter monitoring
Screw cap
Fine filter 1
Fine filter 50
Filter change:
 Unscrew the cap nut
 Remove and dispose of the filter
 Insert the new filter cartridges
 Tighten the cap nut
 Damaged filter cartridges can not be reused
All the filters mentioned must be disposed of in accordance with statutory regulations.