deconta WM 400 V Manual Book

Water treatment instantaneous water heater system

Advertisement

Quick Links

Water treatment instantaneous water heater system
Producer:
Description:
Type No.:
Serial-No.:
Guide book
WM 400 V
deconta GmbH
Im Geer 20, 46419 Isselburg
Instantaneous water heater system WM 400 V
25
.................

Advertisement

Table of Contents
loading

Summary of Contents for deconta WM 400 V

  • Page 1 Guide book Water treatment instantaneous water heater system WM 400 V Producer: deconta GmbH Im Geer 20, 46419 Isselburg Description: Instantaneous water heater system WM 400 V Type No.: Serial-No.: ....
  • Page 2: Table Of Contents

    Guide book Instantaneous water heater system WM 400 V Table of contents On page Introduction Basic safety advice Transport and storage Delivery Transport Storage Scope of delivery Scope of delivery by sale and rent Scope of delivery Return delivery after the rental period...
  • Page 3: Introduction

    In case of damages (mechanical or electric) or in a breakdown, deconta can help you in a short term with his express service.
  • Page 4: Basic Safety Advice

    Instantaneous water heater system WM 400 V 2 Basic safety advice deconta has to engage you as the user to follow the guide book and to employ this engineered technology only in accordance with the regulations and not in an inappropriate way! In the event of non-observance, deconta assumes no liability.
  • Page 5: Transport And Storage

    Instantaneous water heater system WM 400 V 3 Transport and storage 3.1 Delivery The waste water filtration plant is delivered from deconta works on a pallet packed with a plastic film. Transport damages have to be documented at once during the handing over of the carrier or another supplier.
  • Page 6: Scope Of Delivery

    Guide book Instantaneous water heater system WM 400 V 4 Volume of delivery for sale and rent 4.1 Scope of delivery The scope of delivery of a water treatment consists in, regardless of whether purchased or rented, unless other arrangements have been made: ...
  • Page 7: Technical Description

    For this reason, persons must leave the area of operation through a lock system and take a shower before they exit. The deconta water treatment assumes the heating of the shower water and takes over the filtering of the contaminated sewage water 5.2 Device description water treatment...
  • Page 8: Sewage Pump

    "sewage pump start" 5.3.1 Model with 2 waste water pumps Optionally, the WM 400 V can be equipped with a second sewage pump. This sucks in parallel with the first sewage pump the contaminated shower water through a separate filter and pumps it then subsequently through the two common fine filters. Typical use...
  • Page 9: Waste Water Filter System

    Guide book Instantaneous water heater system WM 400 V 5.4 Waste water filtration plant The waste water filter system is used for filtration of contaminated shower water. In the three-stage filtration system consisting of a pre-filter (220), a pressure gauge for filter monitoring and two fine filters (50, 1), the water is filtered and discharged through...
  • Page 10 Guide book Instantaneous water heater system WM 400 V 5.4.1 Effectivity of the waste water filtration Test: Filter separation winding candle 1 Micrometer 10 11 12 13 14 15 16 17 Mea.point Diameter % Effectivity 0,77 84,3 0,97 90,9 1,22...
  • Page 11: Continuous-Flow Water Heater

    Guide book Instantaneous water heater system WM 400 V 5.5 Instantaneous water heater The instantaneous water heater is completely electronically controlled and heats the water as it flows. The electronic regulation and control unit detect the water flow, the inlet temperature and the temperature selector at the specified outlet temperature.
  • Page 12: Technical Data

    Guide book Instantaneous water heater system WM 400 V 6 Technical data 6.1 Water treatment: Length x Width x Height 550 x 680 x 710 mm Weight 57 kg Power supply 400 Volt, 32A 3+N+PE Euro plug CEE-6h Protection level...
  • Page 13: Initial Operation

    Guide book Instantaneous water heater system WM 400 V 7 Initial operation 7.1 Connection assignment to the personal lock system Quick-Dush  Establish the current supply of the water management (400V, 32A 3+N+PE)  Establish the fresh water supply of the water management to the connection “fresh water filling”.
  • Page 14: Maintenance And Care

    Guide book Instantaneous water heater system WM 400 V 8 Maintenance and care The suction hoses, pumps, filter housings and filter are contaminated after the first use. Repairs and maintenance have to be executed only under the observance of all relevant safety measures.
  • Page 15: Geyser

    For the activation of the safety limiter, after the remedy of a previous disorder, a screwdriver or similar should be introduced through the opening of the cap and carefully pressed until the limiter clicks. Opening for screwdriver Information: Upon request, deconta concludes a service contract with you. Page 15 from 17...
  • Page 16: Possible Disturbances And Their Repair

    Guide book Instantaneous water heater system WM 400 V 9 Possible disorders and their corrections Fault Possible cause Corretion Repair by a Shower water too hot Faulty electronics professional Power supply see Shower water too cold Faulty power supply chapter 6.1...
  • Page 17: Proposal Text

    Guide book Instantaneous water heater system WM 400 V 10 Proposal text Water treatment system „instantaneous water heater“, to work for use in asbestos remediation. Transported on castors with fixing device. Easy to clean, powder-coated sheet metal housing. Infinitely adjustable shower water temperature 30°C and 60°C.

Table of Contents