deconta WM 400 V Manual Book page 10

Water treatment instantaneous water heater system
Table of Contents

Advertisement

Instantaneous water heater system WM 400 V
5.4.1 Effectivity of the waste water filtration
Test: Filter separation winding candle 1 Micrometer
100
4
3
2
90
1
80
70
60
50
40
30
20
10
0
Guide book
8
9
10 11 12 13 14 15 16 17
7
6
5
Mea.point
Diameter in Micrometer
Diameter
1
0,77
2
0,97
3
1,22
4
1,54
5
1,93
6
2,44
7
3,07
8
3,87
9
4,87
10
6,14
11
7,74
12
9,75
13
12,28
14
15,47
15
19,49
16
24,56
17
30,94
% Effectivity
84,3
90,9
93,5
95,0
96,2
97,4
98,5
99,7
99,8
100,0
100,0
100,0
100,0
100,0
100,0
100,0
100,0
Page 10 from 17