To reach 40ºC (104ºF), the heating duration required is base on the starting water temperature and ambient
temperature, the data below is purely for reference. To display the current water temperature, run the filter
system for at least a minute.
Ambient Temperature
10ºC(50ºF)
15ºC(59ºF)
20ºC(68ºF)
25ºC(77ºF)
30ºC(86ºF)
Be sure to cover the spa with the spa cover whenever the
heating function is activated. Leaving the spa uncovered will
increase the heating duration required.
Please do not use the spa when ambient temperature is
lower than 4ºC (39ºF).
Power Rate
Massage Tube Power
220-240V AC,
50Hz, Single Phase
2,050W at 20ºC
Selected Location
Indoor and outdoor & above ground & portable wiring &
portable spa
WARNING: The selected location has to be able to support
of supporting the expected load.
WARNING: An adequate drainage system has to be provided
to deal with overflow water for both indoor and outdoor
installations.
• Always keep the spa cover on to minimize heat loss during
heating of the spa between uses (but not while it is being
used). Ensure the cover is fitted tightly, as per instructions
to maximize insulation. It shall be recommended that the
cover, when not in use, should be kept off the ground to
retain its cleanliness (particularly the surface in close
proximity to the water spa water surface). The cover should
be stored in an appropriate location, where it cannot be
damaged, or cause damage.
• Check the set water temperature and consider lowering it
for the times when the spa will typically not be in use.
• Depending on external conditions, consider turning off the
heater entirely if not using the spa for an extended period of
time (where the spa provides this option, but still maintains
residual disinfection/pH-values).
• It is recommended to use an insulating ground cloth
underneath the spa to minimize heat loss through the
bottom of the spa.
303021221099_14x21cm_54112GB; 54123GB; 54129GB; 54148GB; 54154GB; 54174GB; 54175GB; 54183GB; 54186GB; 54286GB; 54291GB_20季英规AirJet SPA主体说明书英
IMPORTANT !
Water Temperature
Set Temperature
10ºC(50ºF)
40ºC(104ºF)
15ºC(59ºF)
40ºC(104ºF)
20ºC(68ºF)
40ºC(104ºF)
25ºC(77ºF)
40ºC(104ºF)
30ºC(86ºF)
40ºC(104ºF)
Heat Element Power
800W
2,000W at 20ºC

INSTALLATION

Heating Duration
18.5 h
15 h
11.5 h
8.5 h
5.5 h
Water Pump Power
50W
8